SciOp

EUROPEAN SOUTHERN OBSERVATORY

SciOp

La Silla - Science Operation Department


Guide to ServiceMode Observing at the ESO/MPG 2p2

Carrying out ServiceMode Observing

A. Daytime/Twilight activities

For WFI:

Start the Nightlog tool now and fill in all relevant informations as close as possible to real time. In the afternoon, the following calibrations must be done:

  • testBias (execute this OB to 'flush' the system before starting with daytime calibration)

  • Bias (execute this OB twice - make sure that lights are off and protective shutter is closed)

  • Dome flats (make sure that no other lamp but the flatfield lamp is on during dome flatfields). In the case of non-standard filters, execute OBs prepared by PI (if any) from their corresponding MTS-queues. If on the previous night you observed with a filter not foreseen during the previous afternoon calibration, then do it now. After you are done with the domeflats, go back to ZERO voltage and then, ADDITIONALLY, PLEASE SWITCH OFF the FF lamp (otherwise the FF fan may be damaged).

  • Twilight flats (you may use xephem to avoid bright stars). Don't obtain twilight flats, if clouds or cirrus are visible in the direction of observation.

    For FEROS:

  • 100 StanCal 225kHz 1 low 1x1 Run this OB in the afternoon, before or after the WFI Dome flats. Make sure, that the lights are off.

  • 200 Solar Spectrum Run this OB about one hour before sunset, pointing to a field 1h east of zenit.

    B. Nighttime activities

  • Pointing correction (done with WFI) is the first activity after evening skyflats. If there is no adequate pointing OB (bright star near zenith at beginning of observations) then choose a bright star (about 4mag), make an OB with P2PP (account 51020 only!), check in, and add this OB to WFI CALIBRATION queue. Don't forget to click on "correct coordinates" in the TCS Setup panel after the pointing OB has been executed!

  • Standard stars (according to Calibration Plan and scheduled programs). The first standard stars will be obtained during evening twilight; during nighttime follow 1 or 2 standard stars (depending on whether short or long nights), and final standard stars during morning twilight. Take care that all standard filters (expected to be) used in science OBs are used for standard stars, in any case use at least a minimum of three different standard filters. The standard star OBs include 7 filters (U360, B99, B878, V, R, I845, and I879). If you use a subset of these filters, ask the TIO to by-pass filters you do not need.

  • Focus (at position of first science OB; preset telescope manually). On a typical night, the FOCUS sequence must be repeated 2-3 times. Therefore check regularly the image quality on RTD.

  • Science OBs Start observing OBs from the execution sequences prepared in the afternoon. Check the weather conditions and make sure that all observing constraints are fulfilled. If no rank-A OB can be executed under the given conditions, switch to rank-B queue. During the whole night, keep an eye on seeing and sky conditions to judge, which programs to observe. If the seeing improves during the night make sure that you switch to a program that requires good seeing. Remember that this is one of the main motivations of ServiceMode observing.

    If you switch between FEROS and WFI, don't forget the setup of the M3.

  • Include all WFI observations in the Nightlog.

    C: End of night

  • Write summary of the night in the comment fields of Nightlog. Any relevant comments, general conditions and eventual time loss should be mentioned here (bad weather, technical, Idle if no OB can be executed under the present observing constraints). Note down the time you spent on FEROS in the field "Others".

  • Save Nightlog. After editing all the required fields in the (remedy) Nightlog and submitting all executed OBs, you are ready to print the Nightlog by clicking on Print Complete Report at the bottom. Choose a non-existing printer (e.g. "xxx") to not paperprint the log.

  • Log into kila as lasilla, go to the directory ~lasilla/220/wfi/WFIServiceObserving/LOGS_all_periods, and move the logfile from the /tmp directory there (e.g. mv /tmp/esompi220_yyyy-mm-dd.rep. ).

  • Run the script service.pl via ../Sripts/service.pl yyyy mm dd epu-password

    The night report will be saved on epu as before and emailed to usg@eso.org and ls-220@eso.org.

  • Note that we no longer keep a printed copy of the Nightlog.

  • Every night must be properly closed before the astronomer and TIO can leave. Furthermore, the status of all executed OBs should be either 'X, or M' (X-successfully executed ; M-must be repeated). Change all OBs with status 'A, I, and S' to one of the above ones. Don't forget to SAVE all MTS-queues after these changes and before calling quits.


    Comments
    [ESO |LaSilla |SciOp |SciOpInternal ]