SciOp

EUROPEAN SOUTHERN OBSERVATORY

SciOp

La Silla - Science Operation Department


Guide to ServiceMode Observing at the ESO/MPG 2p2

Using the Nightlog tool (WFI only)

When using the Nightlog tool please follow these guidelines:

  • Select the telescope. This is also a reset of the general page, so don't select again after filling in the different fields. At the end, click submit button.

  • For general remarks, use the general page of the Nightlog. For afternoon and twilight calibration, use the page named daytime activities. From the pointing correction on use the page named nighttime activities.

  • Enter the OB number and hit return. The information to the OB should be read from the database. Use cut and paste to include the output of the logfile into the field "Files & Additional information".

  • For each exposure put the seeing FWHM as measured with RTD in the image below the file-information.

  • After an OB has been completed, assign a grade to it:
    Bias, Dome/Sky--flats are filled into daytime activities and are judged valid or not valid.
    Pointing, Focus are filled into nighttime activities and are always judged X.
    Standard Calibration Plan are filled into nighttime activities. The only important information is the transmissivity of the night, hence, ignore the other points in the log. If photometric, judge A, if not photometric, judge B.
    Science OBs are filled into nighttime activities. Judge them A, B, or C, depending on whether the executed OB fulfills all the constraints (A), does not fulfill all the constraints, but you judge it acceptable (B), or whether it does not fulfill the constraints and must be repeated (C). Exceptionally you may also assign grade (D) to an OB, if for any reason it should not be repeated although the observing constraints were not fulfilled. In this case, the OB will be cancelled (status: K).

  • If the seeing varies during execution of an OB, calculate the mean seeing of the individual frames belonging to one OB. If this mean value is below the seeing constraint given in the OB, it is obviously Class A. If the mean value is within 10% to 20% above the given seeing contraint, then it is the decision of the observer, whether to classify it as B or C. Such a decision may depend on the scientific proposal. This 10% to 20% tolerance should not be applied, if any explicit statement on seeing is given in the Readme file provided by the PI (e.g. a frequent comment is: please consider the given seeing constraint as true upper limit. In this case you should start the OB only if you think that the seeing will be good enough and stable until completion of the OB.

  • Make sure to submit each OB. Some of the fields must be filled in, otherwise, when you click on submit you will get an error message. Once you have submitted the data it is saved in the database. If you don't click submit - the data you have entered is lost.

  • To edit an entry after having submitted, double click on the OB in the OB list at bottom of the page (pops up a purple window that you can edit - remember to save before closing the window.


    Comments
    [ESO |LaSilla |SciOp |SciOpInternal ]