When using the Nightlog tool please follow these guidelines:
Select the telescope. This is also a reset of the general page,
so don't select again after filling in the different fields. At the
end, click submit button.
For general remarks, use the general page of the Nightlog.
For afternoon and twilight calibration, use the page named
daytime activities. From the pointing correction on
use the page named nighttime activities.
Enter the OB number and hit return. The information
to the OB should be read from the database. Use cut and paste to include
the output of the logfile into the field
"Files & Additional information".
For each exposure put the seeing FWHM as measured with RTD
in the image below the file-information.
After an OB has been completed, assign a grade to it:
Bias, Dome/Sky--flats are filled into
daytime activities and are judged valid or not valid.
Pointing, Focus are filled into
nighttime activities and are always judged X.
Standard Calibration Plan are filled into
nighttime activities. The only important information is
the transmissivity of the night, hence, ignore the other points in the log.
If photometric, judge A, if not photometric, judge
B.
Science OBs are filled into
nighttime activities. Judge them A,
B, or C, depending on whether the executed
OB fulfills all the constraints (A), does not fulfill
all the constraints, but you judge it acceptable (B),
or whether it does not
fulfill the constraints and must be repeated (C).
Exceptionally you may also assign grade (D) to
an OB, if for any reason it should not be repeated although the
observing constraints were not fulfilled. In this case, the OB
will be cancelled (status: K).
If the seeing varies during execution of an OB, calculate the mean
seeing of the individual frames belonging to one OB.
If this mean value is
below the seeing constraint given in the OB, it is obviously Class A. If
the mean value is within 10% to 20% above the given seeing contraint,
then it is the decision of the observer, whether to classify it as B or
C. Such a decision may depend on the scientific proposal.
This 10% to 20% tolerance should not be applied, if any explicit
statement on seeing is given in the Readme file provided by the PI
(e.g. a frequent comment is: please consider the given seeing
constraint as true upper limit.
In this case you should start the OB only if you think that the seeing
will be good enough and stable until completion of the OB.
Make sure to submit each OB. Some of the fields must be
filled in, otherwise, when you click on submit you will get an
error message. Once you have submitted the data it is saved in the
database. If you don't click submit - the data you have entered is lost.
To edit an entry after having submitted, double click on the OB
in the OB list at bottom of the page (pops up a purple window that you
can edit - remember to save before closing the window.