next up previous
Next: Some reference images Up: Procedures Previous: SOFI Collimator Recovery Procedure:

Special Dome Flat

To be sure that the Special Dome Flat you are taking are good: a 8 exposures sequence looks like that :

Figure 9: 1- LAMP OFF; 2- LAMP OFF WITH MASK; 3- LAMP ON WITH MASK; 4-LAMP ON
Figure 10: 1- LAMP ON; 2- LAMP ON WITH MASK; 3- LAMP OFF WITH MASK; 4-LAMP OFF
\framebox{\includegraphics[width=0.20\linewidth]{flat_off.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_off_mask.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_on_mask.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_on.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_on.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_on_mask.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_off_mask.ps}} \framebox{\includegraphics[width=0.20\linewidth]{flat_off.ps}}



2003-03-27