(valid for Period 81, April 1st, 2008 - Sept 30th, 2008).
| Telescope | Focus | |||
|---|---|---|---|---|
| Nasmyth A | Cassegrain | Nasmyth B | Interferometric | |
| UT1 (Antu) | CRIRES | FORS2 | ISAAC | |
| UT2 (Kueyen) | FLAMES | FORS1 | UVES | |
| UT3 (Melipal) | Visitor | VISIR | VIMOS | |
| UT4 (Yepun) | HAWK-I | SINFONI | NACO | |
| AT1 | ||||
| AT2 | ||||
| AT3 | ||||
For details pls. refer to the Call for Proposal for Period 81
(valid for P81).
| Telescope/Instrument | Action | Time (minutes) |
|---|---|---|
| Unit Telescope | Preset | 6 |
| CRIRES | Acquisition without AO | 3 |
| CRIRES | Acquisition with AO | 5 |
| CRIRES | Read-out | 10%-60% of exp. time |
| CRIRES | Nodding cycle | 0.4 |
| CRIRES | Change of wavelength setting | 3.5 |
| CRIRES | Attached wavelength calibration | 2.5 |
| CRIRES | Attached wavelength calibration and lamp flat | 2 |
| FORS2 | Acquisition (1 cycle w/o exp. time)[1] | 1.5 or 2 |
| FORS2 | Through Slit Image (2 cycles w/o exp. times)[2] | 4 |
| FORS2 | Instrument Setup | 1 |
| FORS2 | Read-out 100kHz binned (spectroscopy) | 0.7 |
| FORS2 | Read-out 200kHz binned (imaging) | 0.5 |
| ISAAC[3] | Instrument Setup, Imaging | 0.5 |
| ISAAC | Instrument Setup, Spectroscopy (incl. slit check) | 4-7 |
| ISAAC | Telescope Offsetting | 0.25 |
| ISAAC | Target Acquisition | 1-4 |
| ISAACHw | Read-out (per DIT, imaging) | 0.07 |
| ISAACAl | Read-out (per DIT, imaging without chopping)[5] | negligible |
| ISAACHw | Read-out (per DIT, spectroscopy) | 0.13 |
| ISAACAl | Read-out (per DIT, spectroscopy without chopping)[6] | negligible |
| ISAACAl | Imaging with chopping | 40%[4] |
| ISAACAl | Spectroscopy with chopping | 30%[4] |
| ISAAC | Night time flat[7] (one on-off pair) | 4 |
| ISAAC | Night time arc[7] (one on-off pair) | 3 |
| ISAACAl | Burst and FastJitter Modes | See the Burst web page |
| FLAMES | Acquisition[11] | 9 |
| FLAMES | Instr. Setup GIRAFFE | 1 |
| FLAMES | Instr. Setup UVES | 1 |
| FLAMES | CCD read-out GIRAFFE | 1 |
| FLAMES | CCD read-out UVES | 1 |
| FLAMES | Screen Flatfields | 7 |
| FLAMES | Plate Configuration[12] | 0-20 |
| FORS1 | Acquisition (1 cycle w/o exp. time)[1] | 1.5 or 2 |
| FORS1 | Through Slit Image (2 cycles w/o exp. times)[2] | 4 |
| FORS1 | Instrument Setup | 1 |
| FORS1 | Retarder Plate Setup per PMOS/IPOL OB | 1 |
| FORS1 | Read-out 100kHz binned (spectroscopy) | 0.7 |
| FORS1 | Read-out 200kHz binned (imaging) | 0.5 |
| UVES | Instrument Setup | 1 |
| UVES | Acquisition. Bright Point Source | 2 |
| UVES | Acquisition. Faint, Extended or Crowded Field | 5 |
| UVES | Read-out[8], 1x1, Fast | 0.75 |
| UVES | Read-out[8], 2x2, Slow | 0.75 |
| UVES | Attached ThAr, Night time | 1.5 |
| UVES | Attached Flat, Night time | 2 |
| VISIR | Imaging target acquisition (incl. instrument setup): | |
| VISIR | fine acquisition (>1 Jy source) | 5 |
| VISIR | blind preset (<1 Jy source) | 2 |
| VISIR | Imaging read-out/chopping | 50% of int.time |
| VISIR | Burst read-out/nod-chopping | 80% of int.time |
| VISIR | Spectroscopy target acquisition (incl. instrument setup): | |
| VISIR | >1 Jy source | 15 |
| VISIR | 0.2 - 1 Jy source | 30 |
| VISIR | Spectroscopy read-out/chopping | 50% of int.time |
| VIMOS | IMG acquisition + Instrument setup | 3 |
| VIMOS | MOS acquisition + Instrument setup | 15 |
| VIMOS | IFU acquisition + Instrument setup | 10 |
| VIMOS | Read-out IMG,MOS,IFU (4 quadrants) | 1 |
| VIMOS | Change of Filter (IMG) | 3 |
| VIMOS | Attached screen flat+arc (IFU, MOS)[9] | 5-8 |
| VIMOS | Attached arc (MOS)[10] | 4 |
| SINFONI | Acquisition no AO | 3 |
| SINFONI | Acquisition AO (NGS) | 2 + 4*(DIT*NDIT)[13] |
| SINFONI | Acquisition AO (LGS) | 15 + 4*(DIT*NDIT)[13] |
| SINFONI | Acquisition target (AO and no AO) | 4 + 4*(DIT*NDIT) |
| SINFONI | Instrument setup (per grating change) | 2.5 |
| SINFONI | Science exposure read-out (per DIT) | 0.07 |
| SINFONI | Detector setup (per DIT x NDIT) | 0.3 |
| HAWK-I | Target acquisition | 3 |
| HAWK-I | Telescope offset | 0.15 |
| HAWK-I | Read Out (per DIT) | 0.03 |
| HAWK-I | Filter Change | 0.35 |
| NACO | see User's Manual | --- |
| MIDI | One calibrated Visibility[14] | 60 |
| AMBER | One calibrated Visibility (LR-HK mode)[14] | 90+30*(number of bands)[15] |
| AMBER | One calibrated Visibility (MR-K mode)[14] | 90+30*(number of bands)[15] |
| AMBER | One calibrated Visibility (HR-K mode)[14] | 90+30*(number of bands)[15] |
[1] Typically one cycle for the target acquisition (exposure time of the acquisition image not included). MXU, MOS, and PMOS: 2 min. LSS,IPOL,ECH: 1.5 min (per cycle). IMG none.
[2] Through-slit exposures are mandatory for all spectroscopic OBs. Two cycles are typically enough to center the target on the slit (exposure time of the through slit image not included). MXU,MOS,PMOS,LSS,ECH 2.0 min (per cycle), IMG and IPOL none.
[3] ISAAC refers to both Aladdin and Hawaii, ISAACHw only to Hawaii detector, ISAACAl only to Aladdin detector.
[4] Global overheads in % are used for the LW imaging and spectroscopic chopping templates.
[5] For the Aladdin SW J+Block,H,K and LW low background NB_3.21 and NB_3.28 filters only.
[6] In Medium Resolution (MR) only.
[7] When required, see ISAAC P2PP page and the ISAAC user manual.
[8] In a dichroic exposure the CCDs are read out in parallel.
[9] Flat and arcs are mandatory for IFU.
[10] Arcs are mandatory for MOS blue settings and strongly recommended for the MOS red settings.
[11] Includes configuration of UVES fibres, homing the rotator to zero degrees, swapping of the plates, and the acquisition of field; telescope preset, acquisition of the guide star, and start of the active optics are not included and account with additional 6 minutes. For ARGUS fast acquisition (VM only), the acquisition overhead is 2 minutes and is calculated assuming that plate 2 is already attached to the telescope.
[12] Plate configuration takes 20 minutes at most (Medusa fibres). This does not translate into additional overheads if the running exposure on the other plate is at least 20 minutes long. Plate configuration overheads have to be added if the exposure time is shorter than 20 minutes.
[13] here: DIT and NDIT as required for the AO natural guide star (NGS).
[14] This time includes all telescope and instrument overheads as well as the integration times on the science target and the calibrator.
[15] With a maximum number of 3 bands per wavelength setting. For each new wavelength setting, a new calibrated visibility has to be obtained.