| Interlock |
Source |
Action |
| Platform
carriage back |
Top
unit carriage not fully back in park position |
Check all
top unit carriages on platform |
| Ball
Switch 7 degrees |
The
telescope was driven to an altitude below 7 degrees |
Put telescope
in OFF-LINE mode. Change override
switchto override position and move the telescope manually
upwards. Once the condition is cleared, change the override switch
to its normal position. |
| Emergency
switch |
An emergengy
switch is active |
Release corresponding
emergency switch.
Note: "Switch on rack" could also be the
one in Control Room. |
| East (west, north,
south) Limit |
The telescope has reached
a hardware limit |
Put telescope in OFF-LINE
mode. Change override
switch (rear of rack "A" TCS) to override position and move
the telescope manually upwards. Once the interlock condition is
cleared, change the override switch to its normal position. |