WFI Protective Shutter Remote Control
On the same ADAM-6060 module used to to do the remote filter wheel unit
reset, commands and satus readout for the WFI protective shutter
were implemented. Also an additional selection switch was installed in
the controller to define the LOCAL or REMOTE shutter control mode.
Procedure
- On WFI Filter and shutters controller set control mode switch to REMOTE
- Back to RITS 220 Operation PC and check the ADAM I/O interface
running
- Select the Filter Wheel Adam-6060 (134.171.122.203)
- Check Digital Intput bit DI-2
OFF (Remote mode)
- To Open or Close use the following outputs bits sequences:
OUTPUT BITS DO-n
|
INPUTS
BITS DI-n State
|
|
OPEN
- DO-2 ON
- DO-3 ON
- Wait shutter State OPEN
- DO-3 OFF
- DO-2 OFF
CLOSE
- DO-3 ON
- Wait shutter State CLOSE
- DO-3 OFF
|
DI-2
|
DI-1
|
DI-0
|
REMOTE
CONTROL
|
OFF
|
ON
|
OFF
|
CLOSED
|
OFF
|
ON
|
ON
|
MOVING
|
OFF
|
OFF
|
ON
|
OPEN
|
DI-2
|
DI-1
|
DI-0
|
LOCAL
CONTROL
|
ON
|
ON
|
OFF
|
CLOSED
|
ON
|
ON
|
ON
|
MOVING
|
ON
|
OFF
|
ON
|
OPEN
|
|