[ ESO ] La Silla

2p2-m Telescope
SciOp
WFI Calibration Plan Page


Overview:

The plan we ar using has two components: Instrument Calibration and Standard Calibration. The notes on this web page are based on (but supercede) the short document WFI Calibration Plan of February 2001.

The public WFI Calibration Plan web page provides links to the results.



Instrument Calibration:

Instrument Calibration aims solely to provide data to quantify instrument behaviour for the information of the Team. It does not aim to supply calibrations for use in reduction. However, these Instrument Calibration data are available to users through the links below. The analysis of Instrument Calibration data is undertaken mostly by us.

Instrument Calibrations are grouped in terms of Short, Medium and Long-Term Calibrations:

Short-Term Calibrations Status Frequency Contact Execution Notes Analysis Notes
CCD Bias Levels,
Gains, Read-Noises
(Daily Health Check)
Running Daily F. Selman * How to run it
* Daily Health Check OB
* Daily Health Check analysis script
* Daily Health Check plotting script
Image Quality Database Running Hourly (at night) L. Germany * Image quality input page
* README notes
* Script to read input from web page
* Script to plot results requested via web plot interface
Pointing Reproducibility
(Nightly Health Check)
Scripts Ready Nightly L. Germany * How to run it
* OB for Template Field No. 1
* README notes
* nightlyhealthcheck.pl script to process data
Image Quality Across Mosaic
(Nightly Health Check)
Scripts Ready Nightly L. Germany * How to run it
* OB for Template Field No. 1
* README notes
* nightlyhealthcheck.pl script to process data
Differential Throughput Measurements
(Nightly Health Check)
Scripts Ready Nightly L. Germany * How to run it
* OB for Template Field No. 1
* README notes
* nightlyhealthcheck.pl script to process data
(Weekly Health Check) Current data
not transferred
Weekly F. Selman * How to run it
* Weekly Health Check OB
.



Standard Calibration:
(PIs of Service Mode Programmes take special note)

Standard Calibration frames are science calibrations taken on a routine basis in order to determine photometric zeropoints in UBVRI. They consist of three or four Landolt standard star fields taken throughout the night in all or part of UBVRI, with associated dome, twilight flats and biases. They are taken on each photometric night in which Service Mode programmes of matching UBVRI are also being observed.

The analysis of Standard Calibration data is not undertaken by MET but by the users who need it to calibrate their Service Mode data. Standard Calibration data are distributed to the relevant users as calibration frames with their programme data. Service Mode users requiring UBVRI photometry need not request them and are not charged the time for them. They also contribute (in part) to the Instrument Calibration. Any science calibrations outside of our Standard Calibration plan (e.g. flux calibration in H-alpha; more comprehensive UBVRI photometry; narrowband twi-light flats) are termed Non-standard Calibrations, and must be requested through Observation Blocks. Users requiring such calibrations are charged the time taken by them. These calibrations are not a part of our Calibration Plan.

Standard Calibrations Status Frequency Execution Notes
Landolt Fields Running on SM nights 3 hourly UBVRI or some subset
as the programmes require
Twilight Flats Running on SM nights Daily UBVRI or some subset
as the programmes require
Dome Flats Running on SM days Daily UBVRI or some subset
as the programmes require
Bias Frames Running on SM days Daily UBVRI or some subset
as the programmes require


[Observing] [ESO La Silla]  [The 2p2 Team Home Page ]  [ESO]  [Index]  [Search]  [Help]  [News]