SciOp

EUROPEAN SOUTHERN OBSERVATORY

SciOp

La Silla - Science Operation Department


ANALYSIS OF THE RELATIVE EFFICIENCY OF HARPS

2004-07-26 Xavier Haubois

Abstract

From January to late July 2004, 55 observing nights using the 3.6 meter telescope and its high resolution echelle spectrograph Harps were analysed. The main goal of this study was to define a relative efficiency in terms of the number of counts measured by the HARPS exposure meter and to understand the varations of this latter against various parameters like the seeing, the altitude, the hour angle, in order to optimize the future operation of HARPS and to monitor its stability,
For each data file acquired, relevant informations were obtained from the headers of the FITS files and from the online Astronomical Database Simbad. Others physical parameters were then derived by computation using MIDAS et Unix shell scripts. A list of all these quantities is given in Table 1.

Introduction

In order to be able to evaluate the relative system efficiency, ideally, the signal to noise ratio (S/N) should be measured for several wavelengths and this compared with the S/N predicted by the Exposure Time Calculator (ETC). The ETC was not available as a standalone package to be run in batch mode at the time of our work, so we had to use the HARPS exposure meter, with an integration time of one second, as a backup solution. What is called here "relative efficiency" would be affected by possible configuration changes in the system (telescope + instrument) as well as the weather conditions.

Definition of the HARPS relative efficiency

We are interested in the efficiency relative to some reference observations which were obtained during the first commissioning of HARPS. At that time the number of counts obtained by the exposure meter for a star of a given magnitude was recorded. The night was clear and the seeing around 1".

We define a relative efficiency by the ratio of the average number of counts obtained by the exposure meter during the scientific exposure by an empirically predicted flux corrected by the extinction and the seeing (responsible for fiber losses). The predicted flux has been calculated taking into account that on a clear night with a seeing of about 1" a 10 magnitude star gives a reference level of 4517 counts. Effectively this can be considered as an arbitrary, convenient "normalization". Using the paramters defined in Table 1, we can write the relative efficiency as follows :


SciOp

Notes :
- The extinction coefficient used is 0.133 (V band); it has been taken from EFOSC2 measurements on photometric nights. This information is available on the EFOSC2 page.
- The flux losses due to the fiber are computed by integrating between the fiber edges (1" diameter) and squaring a one dimensional gaussian, centered at the fibre center and with standard deviation computed via the seeing.
- We also assumed that the colour term correction has a negligible effect in comparison with the extinction correction.

Table 1 : Index of the various relevant quantities

Parameter description Name of the MIDAS column Origin (where and how they have been obtained)
Magnitude of the object : MAG From Simbad, the online Astronomical Database
Exposure meter average counts : CTMEAN Header keyword INS.DET1.CTMEAN
Exposure meter maximum counts : CTMAX Header keyword INS.DET1.CTMAX
Exposure meter minimum counts : CTMIN Header keyword INS.DET1.CTMIN
Seeing at the beginning of the exposure (arcsec) measured by the DIMM : SEEING_START Header keyword TEL.AMBI.FWHM.START
Seeing at the end of the exposure (arcsec) measured by the DIMM : SEEING_END Header keyword TEL.AMBI.FWHM.END
Average seeing (arcsec) : SEEING Calculated by averaging the seeing at the beginning and at the end of the exposure
Airmass at the beginning of the exposure : AIRM_START Header keyword TEL.AIRM.START
Airmass at the end of the exposure : AIRM_END Header keyword TEL.AIRM.END
Average airmass : AIRM Calculated by averaging the airmass at the beginning and at the end of the exposure
Telescope altitude (degrees) : ALT Header keyword TEL.ALT
Object right ascension : ALPHA Header keyword TEL.TARG.ALPHA
Object declination : DELTA Header keyword TEL.TARG.DELTA
Local sideral time (s) : LST Header keyword LST
Telescope Focus (mm) : FOCUS Header keyword TEL.FOCU.VALUE
Harps Cassegrain Fiber Adapter Temperature (Celsius degrees) : HCFA_T Header Keyword INS TEMP1 VAL
Modified Julian date (day) : MJD Header keyword MJD-OBS
Relative flux entered through a fiber of one arcsec diameter and corrected by the seeing : PCTFlux Calculated from the average seeing and using the error function
Hour angle (hour) : HA Calculated from the Local Sideral Time and the right ascension
Predicted Flux : PredFlux Calculated from the magnitude on the basis that an object of Mv=10 gives on average 4517 exposure meter counts.
Relative efficiency : EFF This quantity is defined above

.

Results

In this section, we present the variations of the relative efficiency and of the focus against critical parameters. The following plots show the data after binning.

1-Relative efficiency versus seeing

SciOp

One of the most interesting outcome of this study is the shape of the relative efficiency against the seeing. We predicted a scatter around a constant efficiency. As expected, it is fairly flat and it thus shows that we are properly taking into account systematic effects due to the seeing and the airmass. More importantly the plot indicates that there are no unknown effects that degrade the efficiency of the system. The fact that the values of the efficiency differs from 1 simply shows that the observing conditions during these nights were different from the conditions of the (photometric) night in which the reference observations were taken. Anyway, we are interested in the shape of the curve rather than in the absolute value of the relative efficiency.


Top of the page



2-Relative efficiency versus hour angle

SciOp

The relative efficiency as a function of hour angle also behaves in the way we thought: the efficiency is more or less constant around Zenith and drops for high hour angle (high airmass). However the drop is appearing too early, for an hour angle of 3, while we would have expected it to appear around an hour angle of 4 (airmass = 2).

Top of the page



3-Relative efficiency versus the telescope altitude

SciOp

This plot shows again that the efficiency of the system is pretty flat around Zenith and starts dropping considerably for an altitude < 45 degrees (airmass > 1.4). Althought this drop was expected, it seems to appear too early. There are two possible reasons:
- elastic or inelastic deformations of the telescope or
- the Atmospheric Dispersion Corrector (ADC) not functioning correctly.
Indeed for a Zenithal distance of 45 degrees, the length of the diffracted object would be of 1.6" without the ADC correction, and this would lead to a considerable loss of flux from the 1" fiber. The same length should be of 0.11" after the ADC correction, when the ADC is working properly.
These considerations might lead us to investigate once again in detail the proper functioning of the ADC.

Top of the page



4-Focus versus Hour Angle and Altitude

SciOp

Focus varies as a function of hour angle. When the telescope is pointing to the West it seems that flexures are more important than when it's pointing to the East. The position of the best focus seems to change more rapidly when the hour angle is greater than 3 (Altitude < 45 degrees).
The change in the focus position is more pronounced and systematic for Altitudes < 45 degrees (Zenithal distance > 45 degrees). This, combined with the observed drop in the efficiency for Altitudes < 45 degrees seems to point to a flexure problem. It is also suggesting that the optimization of the focus should be done more often, especially when going from low airmasses (Zenithal distance close to 0) to airmasses greater than 1.4 (Zenithal distance > 45 degrees).

Top of the page



Conclusion

This work presents a tool intended to monitor in an automatic way the efficiency of the whole instrumentation, that is to say HARPS and the 3.6 meter telescope.
The relative efficiency behaves as expected and reveals some mechanical features (flexures) of the whole system when we move away from zenith.

This tool shall be useful to estimate quantitatively changes in the efficiency of the system HARPS + 3.6m telescope. Knowing how this quantity evolves is particularly relevant when the instrumentation goes through modifications. The relative efficiency could then be used as a figure of merit to verify whether changes to the insturmentation have improved its performance.

The tool presented in this work could also be useful to optimize operation procedures.


Comments
[ESO |LaSilla |SciOp |SciOpInternal ]

 Top of the page