PRESET ADJUSTMENTS
-
Note
-
All adjustments must be made in the order indicated.
-
If power amplifiers are being adjusted, carry
out all power amplifier settings first.
-
Servo System Offset (5) may be adjusted as required,
always adjust after setting power amps.
-
DO NOT ADJUST P2 AND P4 ON THE PID UNIT AT ANY
TIME.
-
All measurements except step (8) are made at
a telescope elevation of > 15
-
All measurements are made with respect to ground.
| |
Parameter |
Adjust for |
Preset |
Location |
Measuring Point |
Switch Condition |
| 1 |
Tacho Summing Offset |
Tacho FB = 0 volts Monitor |
P1 |
Servo Interface |
AK |
Supply to the |
| 2 |
Current Monitor Offset |
0/P = 0 volts |
P4 |
Servo Interface |
BT |
Power Amplifiers |
| 3 |
Acceleration Offset |
Acceleration FB=0 volts |
P3 |
Servo Interface |
BD |
Switched OFF |
| 4 |
Ramp Circuit Offset |
Ur = 0 volts |
P2 |
Ramp Circuit |
AL |
S=0 |
| 5 |
Servo System Offset |
Power Amp. 0/P = 0 volts |
P3 |
PID Unit |
Power Amp Output |
S=0 |
| 6 |
Preload current |
Motor current = 10 A * |
P2 |
Servo Interface |
Motor Ammeters |
S=0 |
| 7 |
Maximum Slew rate |
Tacho FB=+/- 2.5 volts |
P1 |
PID unit |
BA |
+/- S (3 sec. delay) |
| 8 |
Slew rate at < 15° |
Ui +/- 2.5 volts |
P3 |
Ramp Circuit |
Ui (on PCB) |
+/- S ar <15° |
| 9 |
Acceleration ramp |
Ur= see fig. 1 |
P1 |
Ramp Circuit |
AL |
S=0 initially then +S, or -S |

Fig. 1
|