[ ESO ]

La Silla Observatory

Science Operations
Department
ESO 360 Pointing Procedure


360 Pointing Procedure

After any F35 to F8 top unit exchange or viceverza, pointing measurement and corrections have to be done during the firts setup night in the following sequence:

Determine the Optical axis

The reference position is the telescope optical axis or the image point were the rotation is zero. It has to be determined whenever is possible by the adapter rotation.
  1. Move Guide-probe to center position.
  2. Select any star in the ccdTEC field and center it using telescope offset
  3. Do adapter rotation to the instrument default position and measure the X1,Y1 star position
  4. Do adapter rotation of +/- 180deg. then measure the X2,Y2 star position
  5. Move star to [(X1+X2)/2 ; (Y1+Y2)/2] using telescope offsets and re-measure the X2,Y2 star position
  6. Do adapter rotation to the instrument default position and measure the X1,Y1 star position
  7. Move star to [(X1+X2)/2 ; (Y1+Y2)/2] using telescope offsets and re-measure the X1,Y1 star position
  8. Repeat points 4 to 7 until there is no star rotation
  9. If the reference position is not the ccdTEC center, the Guide-Probe center coordinates have to be re-measured. So just move the guide-probe until the star be in the ccdTEC center and writedown the new guide-probe x,y center in mm. As this new numbers have to be hardcode by SWC, use the NR-Request option to notify them.

Correction Coordinate

Select and point telescope to a star around zenith from the FK5 catalog. If it is not in the field do the standard search procedure and write down the alfa and delta offsets needed to have the target on the reference position. On w3p6tcs account tcs open a xterm and do:
  1. cd /vltdata/config
  2. Copy and edit the ID and CH terms on files pomXX
    if F8,  cp pomCA.dat pomCA.dat_yyyymmdd 
            emacs pomCA.dat
    if F35, cp pomIM.dat pomIM.dat_yyyymmdd
            emacs pomIM.dat
    
  3. Correct pointing terms ID and CH (because signs, 4 iterations may be needed)
    ID = ID - [ Delta_Offset ]   ; Remember offset to the South are negative
    CH = CH - [ Alfa_Offset  ]   ; Remember offset to the West  are negative
    
    To avoid confusion do it one by one
    
  4. On emacs do save file
  5. On TCS status panel do trkws OFF,INIT,ONLINE ; this should reload the pomXX file to the axis LCUs
  6. Do preset again to the same target and check again sign and offset
  7. Repeat point 3 to 6 until be Ok, e.i target on reference position (less than 10 pixels)
Warning: IF ID is out of the range 300 to 500 or CH out of the range -150 to 150, means that M2 is not back on the right position then IQ will be affected. So M2 has to be re-installed according to the reference.

Pointing Measurments Sequence

From any xterm on w3p6agu type e3p6opsStartPomMes &. This procedure will run a remote shell on w3p6tcs to open the e3p6opsPomMes panel and locally will open the panel e3p6opsRtd2.

On e3p6opsPomMes Panel do:

To get full image just click here
  1. Press Load Catalog to load Stars Catalogue (Use fk5.tcs)
  2. Press Load Temp.. to load any of the following template files:
    1. 360PointingTemplate.tpl
      ( more than 50 points)
    2. MeridianSixStars.tpl
      (quick ID,CH measurement)
    3. pomTemplate24.tpl
  3. Press check button Auto Name
  4. Press button Create file
    (Output error file)
  5. Set DUT
  6. Check radius = 100
  7. Check button Auto Preset
  8. Check button Auto Store

On e3p6opsRtd2 Panel do:

To get full image just click here
  1. Select Camera (ccdTEC f8 ccdTEC F35 ccdIMG F8 ...)
  2. Select Centroid method (Standard, Threshold, none)
  3. Press TCCD Setup Button
  4. Check Camera button ON (Guiding camera have to be in infinite loop)
  5. Adjust image scale and cuts using Autocut and Scale buttons
  6. In the Reference Position entry fields, write the X,Y coordinates and press
    button "Draw Box".
  7. Box size by default is 50pix.


Measurements

  1. On panel e3p6opsPomMes press button Next Object to start the sequence measurements. An automatic searching procedure - according to the template file - will get the Telescope coordinates and will move it to the first one on list.

    WARNING:As the Auto Preset and Store commands are set, do not go through the list

  2. Wait both telescope and dome preset done i.e Tracking then on panel e3p6opsRtd2 press button ObjectToBox and move cursor to the target and click on it. The needed telescope offsets will be applied to put the star on the reference position.

    NOTE: If the start is not on the TCCD field, DO point 3. This action will produce an error equal cero on the measurement file and it won't be taken in account for the pointing analysis.

  3. On panel e3p6opsPomMes press button Next Object to measure the telescope position and save it into the file before going to the next target from the template file list.

  4. Repeate points 2 and 3 to complete the template list.

  5. To finish press Close File

On Line Pointing Analysis

Press button 360StdFit to run the 360 tpoint procedure fit. Check the new graphic panel with the pointing error fit and the xterm to see the RMS result. If there are points to edit use button SLIST and MASK to list residuals and to mask bad points. Suggested option is:
mask R > 30

Stand-alone Pointing Analysis (tpoint command line)

Because TPOINT 7.8 version bug, remember that the MA terms has the wrong sign.
  1. Open a xterm
  2. cd /vltdata/pointing
  3. Look for the last data file name just typing ls -1tr DATA/*
  4. tpoint
  5. indat DATA/[--lastdatafile--]
  6. call f8
  7. slist to list residuals
  8. To edit points use mask n , where n is the slist row number
  9. Use fit to fit the new slist
  10. call e9 to plot residuals

Apply Model

To check new model just press button ApplyModel. The new pointing term values will be download to the axis LCUs If all OK, press button Install Model to have the new model saved either on w3p6tcs:/vlt/data/config/pomCA.dat or
w3p6tcs:/vlt/data/config/pomIM.dat


Send comments to <ebarrios@eso.org>
Last update: 23 Jan 2005 
[360Cat home page][3.6m Telescope Tecdoc Page][3.6m Telescope TecDoc page][Index][Search][Help][News]