jP2PP for EFOSC2
Contents
- Pre-Observing (in the La Silla Computer Room)
- At the Telescope Control Room
Only an outline of the steps for running jP2PP is given here, and some of the information below is out of date. Refer
to the Main jP2PP Web Page
for a more detailed description and the latest manual. A description of
different observing modes and the corresponding jP2PP parameters is available
at Observing Modes, as is a list of current templates.
Pre-Observing (in the La Silla Computer Room)
Getting Started
Login as user 360v1 or 360v2 or 360v3
on the machine kila using one of the X-terminals
in the computer room in the main office building below the hotel. The password
may be obtained from the support astronomer.
Type bin/startjp2pp
in the home directory and when prompted type in your P2PP username and
password (usually emailed to you by the support astronomer a few weeks
before your run) and then sit back and relax while the package takes its
time to open the jP2PP workspace panel. If this is the first time the program
will download the details of the observing programme from ESO Garching
and store it on the local disk; on subsequent occasions the locally saved
information will be sufficient for running jP2PP.
Select the appropriate ESO
Observing Period (top right) and
Programme (listed under Folders on
the left) ..... and then you are in business
A Brief Overview of the jP2PP Main Panel
There are 2 types of blocks generated by jP2PP:
ObsBlocks,
which require a target position, and
CalBlocks,
which have no provision for defining a target or an Acquisition template
(the terminology is unforunately a bit confusing since they both generate
what is called an OB or observing
block which is what is used to execute the observations). The two
are catalogued separately and cannot be changed from one type to another.
Select
one or the other by clicking on the appropriate button ;
this will automatically list all the existing OBs of that category (1 OB
in each row).
There are 4 buttons on the top left corner New
to open a new OB, Duplicate to
duplicate an existing OB, Verify
to verify that the OB has been defined without any errors and View
to view /edit the parameters of an OB. The last 3 options require
that an existing OB be selected ; the selected OB is highlighted with white
script on a blue background while the others are black on white. The selection
can be changed by clicking on the desired OB with the left mouse button.
Several fields of each OB are displayed on the main panel. Fields of
relevance to a 3.6m/EFOSC2 user are Name, Target and Acquisition. The widths
of the columns can be changed (using the left mouse button) to display
these fields to the fullest advantage while shrinking the others.
A New CalBlock OB from Scratch
Images of typical OB Panels for each of the EFOSC2 observing modes may
be found by following the links on Observing
Modes.
Step 1
-
Click on CalBlock on the main panel
and then on New --- you
should see a new OB, highlighted in blue, with Name
= No Name
-
Click on View --- this will
open the OB panel where the OB parameters can be defined.
-
Expand the OB panel until all fields are fully visible.
-
Change the Name field from No
Name to something informative
-
Select Calib under
Template
Type and one of the many templates listed under Templates
and then click on the right margin --- you will see all the
parameters of that template being displayed below in 2 columns : a column
of labels (on the left, with the template name on top) and another with
the corresponding values (on the right, with a sequence number on top).
-
Positioning the cursor on a value to display the range of permitted values
and Click on it to edit it
-
Each template will result in one or more images of a given type.
-
..... we now have an OB comprising 1 template
Step 2
-
A second template of the same type may be added by either clicking on Add
(with the same template still highlighted on the top-right) or on Duplicate
to duplicate the one already defined. The latter is usually more appropriate
since many of the parameters stay the same and only a few from the first
one need to be changed to obtain the second one --- the end result
is the column of labels to the left followed by 2 columns of values, numbered
1 and 2; i.e. an OB with 2 templates which will be executed in the order
in which they appear
Step 3
-
In fact the second template can even be of another type. Following Step
A, select another Template on
the top-right corner and click on Add. You'll
see 4 columns in the following order: labels and values of template 1 and
labels and values of template 2
A combination of several Step B and Step C can be used to build an OB with
a variety of templates in the required order. However, indiscriminate mixing
of templates within a single OB, while permitted, is bad practice and could
lead to mix-ups during the night in certain cases; mixing certain
kinds of templates does make for more efficiency but not for all types.
An erroneous definition of an OB will be
indicated by red characters on the OB panel
and a red spot against the OB in the main
panel. The telescope will not be able to execute such an OB.
One can rearrange the sequence of templates in an OB by
the simply dragging a template from its current location to the desired
location using the left mouse button.
An unwanted template may be deleted by clicking on the
Delete
button on the top left.
Note : in case of Duplicate
, Delete and rearranging
the sequence of templates the template in question has to be first
selected by clicking on it (i.e. anywhere on the column with the defined
values).
A New ObsBlock OB from Scratch
This is very similar to generating a CalBlock but for the following
differences:
-
Click on ObsBlock on the main panel
instead of on CalBlock.
-
The OB panel contains the target data section at the bottom of the panel.
-
The OB panel contains an additional set of sub-panels titled
Constraint
Set , Time Intervals , User
Comments and Calibration Requirements.
These are required only for service observing and may be ignored
for 3.6m/EFOSC2.
-
The first template has to be an acquisition template which can be selected
by clicking on Acquisition under Template Type and selecting
one of the available templates in the adjacent column. This template defines
the co-ordinates of the target field, orientation of the field, positioning
of the object on a pixel or a slit and such other features.
-
The subsequent template(s) can be drawn from either the Science
or the Calib category under Template Type though the
former will be the one most often used
A New OB from an Existing OB
Select the OB on the main panel and click on Duplicate
to obtain a replica which only differs in its Name
(original name with an additional numerical suffix). This can then be modified
using the methods described above.
Exporting the OBs into ASCII files
The OBs generated will be stored as binary files in the directory
jp2pp-cache/####.dir
where #### is the P2PP code of the observer.
However these have to be transferred as ascii files across machines. They
can be converted to appropriate ASCII files using the Export option in
the main panel of jP2PP.
-
Create a sub-directory jp2pp-cache/impex/####
where #### is your P2PP user code.
-
Highlight all the required OBs (refer to the jP2PP
manual for highlighting many OBs at once).
-
Select Export found under the
File
button on the main panel and export files to the above sub-directory. This
has to be done separately for ObsBlocks
and CalBlocks
At the Telescope Control Room
Import the previously generated OBs
The support astronomer will assist the observer in this.
-
There should be account visitor
active on the machine w3p6dhs
from an X-terminal in the control room
-
Create the directory ~/cache/impex/####
where #### is the P2PP code of
the observer and FTP the exported ASCII OBs from Kila
into the above directory
-
Start jP2PP with the command jp2pp in
the home directory and input the user code and password when prompted
-
On the main panel select Import
under the button File. In the pop-up
panel move to your subdirectory (~/cache/impex/####),
select all the required OBs and import : the original OBs will
be read into the jP2PP main panel under the appropriate category.
OBs can now be generated, deleted, modified as before
Scheduling Observations
-
The observer only needs to highlight a particular
OB and inform the telescope operator who will pull it across the network
into the machine which controls the telescope and the instrument.
-
jP2PP needs to be idle (with the OB highlighted)
only at the instant when the operator is pulling the OB across. At all
other times the observer can edit and add to his/her list of OBs even when
observations are going on.
-
OBs can be selected in any order with no reference to the sequence in which
they were generated.The only constraint is that jP2PP must be running while
observations are going on.
Some General Comments
After some practice (a couple of hours) one can generate a new OB in
some 5-10 minutes, typically. It is even faster to duplicate an existing
OB and modify the replica. So it is not necessary to have every OB prepared
before a run. A good strategy would be to prepare OBs for the first night
or half night and prepare the rest during the night (provided the observing
programme does not consist of very shoft exposures of a large number of
sources)
Preparing OBs during the run also means that one can fine-tune one's
strategy depending on the observing conditions and experience gleaned from
the first few observations. However this should not be taken to mean that
one should enter the Control Room with no preparation at all!