README web version of /home/usg/OPS/MTS/readme_xml/readme_84111504
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Waiver Requests
Critical Observing Condition Constraints
For this imaging run, we necessitate high angular resolution:
1) Thus we need to be diffracion-limited at 10 microns, which occurs with a seeing
of 0.8" in the optical.
2) Since we image faint structure, we necessitate optimal atmospheric conditions
(photometric) in order to have minimum flux losses.
Time-Critical Aspects
- We necessitate to be diffraction limited in the N band. Thus we requested
observations at low airmass. We would like to have the observations within 1.2 maximum
at periods indicated in Time intervals.
- During data reduction, in order to perform appropriate centering of the 20 mu
image on the 10 mu image at the pointing accuracy of the telescope, it is mandatory
that 20 mu images are done immediately after the 10 mu images, with only the change
of filters between the two set of data.
It is important that this time-critical aspect can be respected.
Special Execution Requirements
Special Calibration Information
For this run, we request the observation of 2 reference stars in the following
order
1) Observation of the reference star HD31767 (NOT part of the CP) BEFORE the science
OB. We submitted a specific calibration OB.
2) Observation of the reference star HD34055 (NOT part of the CP) AFTER the science
OB. We submitted a specific calibration OB for HD34055.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If the provided finding chart is at a different wavelength than the observations,
did you clearly describe in the README file how to identify the target?
Did you specify a guide star brighter than V=12mag within a field of
r=5arcmin around the science target?
Last creation of page: Tue Oct 6 15:40:33 2009
If you have comments, please contact usd-help@eso.org