README web version of /home/usg/OPS/MTS/readme_xml/readme_82504800
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
- VRI,NB imaging and Spectroscopy of comet C/2007 N3 Lulin
- This program should be execute as close as possible with the other program 282.C-5048(B),
for JHK imaging with SOFI.
- This program consists of three sets of OBs, (MOV_Lulin_VRI_ima_?, MOV_Lulin_NB_ima_?,
with ? = 1 for the first set, same with 2 the second set, and 3 for the third)
THAT SHOULD NOT BE EXECUTED ON THE SAME NIGHT, but likely on three succesive nights,
to check comet variability.
- The spectroscopic OBs have to be executed one night only, likely during the one
of the night of image observations
- Please insert appropriate coordinates & proprer motion of the Comet, as given
in the ephemeris file. The comet coordinates given in the OB are approximate one,
to be used only for scheduling!
- Please, since Comets are always unpredictable, check that the photometric center
is not saturated.
- Comet integrated V is of the order of 8
The Obs named MOV_Lulin_NB_ima_? are with Narrow band filters (Cometary) #837(Bcont)
and #840 (Rcont)
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Last creation of page: Tue Oct 6 15:40:28 2009
If you have comments, please contact usd-help@eso.org