README web version of /home/usg/OPS/MTS/readme_xml/readme_82094201
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
In order to confirm, the presence of an hot spot in the FU Ori system,
one needs to detect the modulation detected in Malbet et al. (2005). We propose
therefore to observe with two different configurations: A0-K0-G1 and A0-D0-H0 with
hour angles ranging respectively from -1h to +3h and from -0.5h to +1.5h (corresponding
to the uv coverage available for this target decliantion, see http://www.eso.org/~mwittkow/delayrestr.html)
at low spectral resolution in order to get color information on the resolved structure.
We would like to have the best uv coverage and therefore we want to aletrenate during
2h the scientific target with a calibrator (the primary calibrator is HD 42807,
but there is also an additional one, HD 38529, that can be done from time to time
instead of HD 42807). It is important to have the quickest sci/cal aletrnance in
order to get a good sampling of the uv track.
Waiver Requests
No Waiver Request was submitted. We asked the baseline to be changed because
of an error in P1 proposal (baseline in immediate objective, box 8B, was not the
same than the one in box 15). As a matter of fact the objet would not be observable
if the baseline is not changed.
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Normally the time allocated does not allow the target to be observed two
times, but nominal time with cal-sci-cal observations account only for 1h45. Therefore
if time allows it (e.g. end of night with no other program to observe), I would
like to do cal1-sci and sci-cal2 which counts for 2h20. M. Wittowski advised me
to prefer the cal1-sci-cal2 combination with 2 science templates in it, therefore
a 15mn more.
For sake of consistency, I would like to keep the same 2 calibrators as for the
run A. They are located closed to the source. Since the source is at the edge of
observability for this baseline, it is difficult to meet the requirement of 30min
of calibrator before and after the science observation which I reduced to 20 min,
and also, the requirement of 2h of observing sources that I reduced to 1h45. I hope
this is still acceptable.
Special Calibration Information
It is important to have the quickest sci/cal alternance in order to get
a good sampling of the uv track.
HD 42807 has a diameter of 0.5+/-0.1 mas and HD 38529: 0.4+/-0.3 mas.
I suggest the following sequence:
- CAL_hd38529: 1 science template, 35 min
- SCI_fuori: 2 science templates, 35+15 min
- CAL_hd42807: 1 science templates, 35 min
which gives a total of 2h. Due to DL constrain, it was not possible to have both
calibrator 30 min before and after the SCI LST range. But we arranged to have a
calibrator with a 30min delay before (CAL_hd38529) and one with 30min after (CAL_hd42807).
It is therefore importnat to start with CAL_hd38529, then do SCI_fuori and finally
CAL_HD42807.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:28 2009
If you have comments, please contact usd-help@eso.org