README web version of /home/usg/OPS/MTS/readme_xml/readme_82094200
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
In order to confirm, the presence of an hot spot in the FU Ori system,
one needs to detect the modulation detected in Malbet et al. (2005). We propose
therefore to observe with two different configurations: A0-K0-G1 and A0-D0-H0 with
hour angles ranging respectively from ?1h to +3h and from ?0.5h to +1.5h (corresponding
to the uv coverage available for this target decliantion, see http://www.eso.org/~mwittkow/delayrestr.html)
at low spectral resolution in order to get color information on the resolved structure.
We would like to have the best uv coverage and therefore we want to aletrenate during
4h the scientific target with a calibrator (the primary calibrator is HD 42807,
but there is also an additional one, HD 38529, that can be done from time to time
instead of HD 42807). It is important to have the quickest sci/cal aletrnance in
order to get a good sampling of the uv track.
Waiver Requests
Critical Observing Condition Constraints
The source is observable only 4h and it is important to sample the uv
track from LST 4:45 to LST 8:45 in order to get useful observations. I have submitted
therefore 3 OBs with the science target that sample the RA: [4:45-6:15], [6:15-7:15]
and [7:15-8:45]. These observations should be surrounded by calibrators measurements.
Time-Critical Aspects
Special Execution Requirements
If possible, I would like the 3 sequences CAL_hd38529_1/SCI_fuori_1, CAL_hd38529_2/SCI_fuori_2/CAL_hd42807_2
and SCI_fuori_3/CAL_hd42807_3 to be done the same night so that it allwos us to
have a well sampled transfer function. However if it is not possible, then the pairs
or triplet can be done in different nights.
Special Calibration Information
It is important to have the quickest sci/cal alternance in order to get
a good sampling of the uv track.
HD 42807 has a diameter of 0.5+/-0.1 mas and HD 38529: 0.4+/-0.3 mas.
We propose the following sequence:
CAL_hd38529_1
SCI_fuori_1
CAL_hd38529_2
SCI_fuori_2
CAL_hd42807_2
SCI_fuori_3
CAL_hd42807_3
Due to DL constrains, sources close to the DL limits and closeby calibrator, the
calibrator CAL_hd38529_1 could not be specified 30min before the SCI LST range,
but only 20min before. I hope this is still acceptable?
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:28 2009
If you have comments, please contact usd-help@eso.org