README web version of /home/usg/OPS/MTS/readme_xml/readme_82081202
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
VIMOS pre-imaging has been requested using the R filter in the surrounding
10'x10' field of view of the central quasars HE1104-1805A and PKS0232-04.
The default 90 degrees rotator on sky will be used. This is to locate targets
prior to a MOS follow-up in order to get spectroscopic redshifts of galaxies at
z~1.
These targets have already been selected using a colour cut from BRI imaging obtained
during run
381.A-0874(A),(C).
There will be 4x345 second exposures during this run. One 345 second image will
be taken along one
line-of-sight before the pointing is moved 3.0'x3.0' in order to cover the VIMOS
chip gap.
THe same routine is then to be used when observing the 2nd quasar.
Waiver Requests
A request was made for these pre-imaging runs to be taken, however they
were not requested during phase I
as it was assumed earlier VIMOS imaging runs would suffice.
The request was made on 29/07/08 with USD ticket number USD-24593.
This request was granted on 30/07/08. Given the short time until the deadline an
extension was granted
for phase II preparation until 7/08/08.
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify suitable guide stars for all your OBs using Guidecam
?
Did you check that the chosen guide stars are suitable for all the offset
positions and that they do not produce unacceptable vignetting of the field of view
?
Last creation of page: Tue Oct 6 15:40:27 2009
If you have comments, please contact usd-help@eso.org