Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
The goal of the program is to spatially resolve and study the geometry
of the emitting gas located in the closest AUs of HAeBe stars where planets are
supposed to form.
We propose to observe the gas in a strong emission line (Brackett Gamma, 2.165microns),
that is for this target at least 30% more luminous than the continuum.
To this goal, we propose observations on MWC158, a B9 star, with AMBER in its medium
resolution mode, with FINITO.
Such observations are of very high importance to constain planet formation models,
and *only* AMBER/VLTI can achieve them.
Observations should be preferably carried with the D0H0G1, but the E0G0H0 triplet
can also be chosen in case it serves the service queue, at the end of the period
where the target can be observed.
Besides, in order to have the OBs verified and checked OK by the system, I had to
put 0.6" as seeing constaints, but I do think that the observations could be carried
until 0.8" (because I already obtained data on a H=5.5, K=4.2 (fainter) target in
MR-K with FINITO on the ATs, with seeing from 0.6" to 0.8").
1.5 hours were obtained for this program, and this corresponds to more than 1 calibrated
point. Therefore, I suggest to integrate *longer* on the target, ie to do a sequence
such as: science-science-calibrator (there are 2 templates in the science OB). In
fact, my experience in visitor mode - in which we did a H=5.5 target in medium resolution
with FINITO - showed that it is necessary to integrate as many target files as possible,
in order to get an unambiguous signal of V2 within the Brackett Gamma line.
These observations are at the limit of FINITO official performances, but can be
achieved with it, in good conditions (seeing <=0.8" and good coherence time).
The fringes are expected to be of high contrasts (even more with the E0-G0-H0 triplet)
but as the target has never been observed, I could not give a very specific value.
If the tracking by FINITO seems very OK, then, the astronomer can integrate up to
2seconds, increasing the SNR in the Brackett Gamma line. But this choice will depend
on the conditions. To be conservative, I put 1second in the OBs.
The calibrator was chosen with CalVin and has a 0.87mas+-0.01mas diameter.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?