README web version of /home/usg/OPS/MTS/readme_xml/readme_82011500
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Direct imaging of three HAWKI pointings in the sigma Orionis cluster using
J, H, and CH4 bands.
The coordinates of each pointing have been selected according to the following criteria:
1) targets fall within the detectors (they do not fall in the detector gaps);
2) there are no very bright stars (H < 9.6 and J < 9.3 mag) within the field-of-view
of HAWKI.
Strategy of the J, H and CH4 observations:
A) 29 images with integration time of 120 seconds (NDIT=12 and DIT=10s for H; NDIT=8
and DIT=15s
for CH4). All 29 images must be jittered/offseted in a box of 12 arcsec.
B) 4 images with integration time of 90 seconds (NDIT=9 and DIT=10s) for J. All
4 images must
be jittered/offseted in a box of 12 arcsec.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates ?
If you are using a specific offset pattern or position angle, did you
check carefully the definition in the manual ?
Did you enter the magnitude of the brightest star in the field-of-view
in the 'Instrument Comments' field of each OB ?
If you use the MoveToPixel acquisition, have you given clear instructions
on the FC and in the OB comment section as to how the field should be centered ?
Last creation of page: Tue Oct 6 15:40:26 2009
If you have comments, please contact usd-help@eso.org