README web version of /home/usg/OPS/MTS/readme_xml/readme_81504400
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This is a test for a new observation and data reduction technique, which
does not require jittering, and therefore allows the usage of shorter MOS slits.
The total observation is split among two identical OBs
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
We would appreciate if this OB could be executed before the deadline for
the submission of MOS VIMOS OBs for period 82, as this test is designed to let us
decide which observing strategy to use for large programme
182.A-0886, PI L. Guzzo
Special Execution Requirements
Special Calibration Information
To better explore our new data reduction technique we need a set of day-time
flat fields covering a large range of illumination intensity. We would need at least
5 flat field exposures where the peak number of counts per pixel in a slit covers
the range from 3000 to 30,000 counts
We have not submitted an OB for this calibration requirement, as the standard calibration
OB does not allow the user to specify the exposure level. Still this calibration
requirement is probably not part of the
standard calibration plan
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify suitable guide stars for all your OBs using Guidecam
?
Did you check that the chosen guide stars are suitable for all the offset
positions and that they do not produce unacceptable vignetting of the field of view
?
Last creation of page: Tue Oct 6 15:40:26 2009
If you have comments, please contact usd-help@eso.org