README web version of /home/usg/OPS/MTS/readme_xml/readme_81068300
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This is a simple imaging run with one image taken on 16 different positions
and with all the same instrument setup (all with R band and with exposure time of
15 seconds). The goal is to perform pre-imaging for an incoming VIMOS observation
run. All the science OBs first point telescope to coordinates with suitable guide
stars and then perform 1 exposure of 15 seconds.
The total exposure is 4 minutes and the execution of all our OBs, based on P2PP,
will take 2 hours and 32 minutes. We are aware that this exceed the approved time
of 0.6 hours for our program. Although we expect the observations to take less then
2.533 hours, we are aware that any additional time needed then the 0.6 hours approved
for pre-imaging will be subtracted from our spectroscopic follow-up run.
There is no OBs for calibration since it is not mandatory in PRE-IMAGING mode.
Waiver Requests
Critical Observing Condition Constraints
Observations needs to be done within +/- 2 hours from the meridian. Therefore,
observations need to be done bellow and airmass of 1.20-1.25 for our targets (all
our targets have declination from -50.6 to -54.4 degree).
The only other constraints are to have a seeing less then 1.2 arcsec, lunar illumination
of less then 0.5 and Moon angular distance of 30 degree or more.
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
There is no OBs for calibration since it is not mandatory in PRE-IMAGING
mode. The calibration frames (bias, sky flats, and photometric standard star observation)
will be delivered to us together with the pre-imaging data when the pre-imaging
run will be completed.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify suitable guide stars for all your OBs using Guidecam
?
Did you check that the chosen guide stars are suitable for all the offset
positions and that they do not produce unacceptable vignetting of the field of view
?
Last creation of page: Tue Oct 6 15:40:25 2009
If you have comments, please contact usd-help@eso.org