README web version of /home/usg/OPS/MTS/readme_xml/readme_81050500
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Below we prioritize the observing blocks for this run:
ONE: IMAGING URANUS IN Q2:
The OBs should be executed in the order:
1. HD216032_ima_Q2-1 (For calibration)
2. MOV_Uranus_ima_Q2-1
3. MOV_Uranus_ima_Q2-2
4. HD216032_ima_Q2-3 (For calibration)
5. MOV_Uranus_ima_Q2-3
6. MOV_Uranus_ima_Q2-4
7. MOV_Uranus_ima_Q2-5
8. HD216032_ima_Q2-5 (For calibration)
NB1: Calibration OBs must be executed before AND after each 2 or 3 sets of Uranus
OBs. Please, adjust this schedule if the airmass is too different from one OB to
the next. If all OBs cannot be executed during the same night, be sure to run at
least one "Calibration" OB (i.e. HD216032_ima_Q2-*) at each time.
NB2: As you stay on the same target between 2 MOV_URANUS OBs, you can increase the
exposure time after the first OB to fit within 1 h.
NB3: Our previous observation in Sept. 2006 showed that you may need to use the
tracking camera at the beginning of the OBs in order to locate Uranus.
TWO: LOW RESOLUTION SPECTROSCOPY (12.4 MICRONS):
The slit should be aligned and centred along North-South polar axis of Uranus.
OBs should be executed in the order:
1. MOV_Uranus_spectro_LR-1
2. MOV_Uranus_spectro_LR-2
3. MOV_Uranus_spectro_LR-3
4. MOV_Uranus_spectro_LR-4
5. MOV_Uranus_spectro_LR-5
THREE: IMAGING URANUS IN Q3:
OBs to be executed in the order:
1. HD216032_ima_Q3-1 (For calibration)
2. MOV_Uranus_ima_Q3-1
3. MOV_Uranus_ima_Q3-2
4. HD216032_ima_Q3-2 (For calibration)
5. MOV_Uranus_ima_Q3-3
6. HD216032_ima_Q3-3 (For calibration)
NB : Adjust this schedule if needed to have similar airmass between HD216032 and
Uranus. Moreover, if two OB on uranus are performed consecutively, increase the
exposure time of the second one to fit the total execution time within 1h.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If the provided finding chart is at a different wavelength than the observations,
did you clearly describe in the README file how to identify the target?
Did you specify a guide star brighter than V=12mag within a field of
r=5arcmin around the science target?
Last creation of page: Tue Oct 6 15:40:24 2009
If you have comments, please contact usd-help@eso.org