README web version of /home/usg/OPS/MTS/readme_xml/readme_81042500
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
JHKs autojitter imaging of 3 planetary microlensing event candidates.
This is the follow-up 2nd imaging epoch of 3 planetary microlensing
discovered and observed with NACO in Period 79 while the events were still
in progress. The events are now at baseline, i.e. the lensing effect has terminated.
The magnification gradient and therefore the brightness difference between epoch
1
(period 79 run) and epoch 2 (this run) will allow us to separate the microlensing
event
from unrelated background sources and so indirectly enable a measurement of the
brightness of
the lens star, the planetary host star. "Indirect" because the lens and source star
separation
is still to small (~1 mas) to be directly resolved, but the high spatial resolution
of NACO will reduce source confusion with unrelated sources in these crowded Bulge
fields.
The constraints from this two epochs together with our microlensing model based
on our light curve data from our telescope network PLANET obtained in P79 will
allow to significantly reduced the uncertainties in the mass of the planet candidate
and its host and their physical separation.
Since the targets are faint we PREFER STRONGLY the use of the LASER GUIDE STAR and
the science OBs for this setup are marked with -LGS- in the OB name.
Targets are observable for the whole period 81.
Good seeing and photometric conditions are crucial.
If for some reason however the Laser will not be operational for the whole period
81,
we prepared a backup setup using natural guide stars. The OBs are marked with -NGS-
in their names.
Further note that target MOA-197 is in nonstandard FNS-HS readout mode and we supplied
a separate photometric calibrator for this target. All other targets (MOA-192 and
O-349)
are in standard DCR-HD readout mode, supported by the calibration plan.
In case of question, do not hesitate to contact me under
dkubas@eso.org
skype: tangonaut
or EXT: 3058 (office vitacura)
+56-2-753 4629 (home)
cheers, Daniel
Waiver Requests
Waiver request 381.C-0425A.01/02.WAV granted
mail from 8.Feb.08:
Dear Daniel, Dr. Cassan,
Your waiver request to submit OBs of durations 1.5-2h was granted
under the usual restriction that an OB will not be aborted or
repeated if conditions degrade below constraints after the first
hour.
In that respect, it is important to optimize the OB duration in
such a way that the program does not suffer too much, even if
a part of an OB is executed with e.g. the seeing higher than
specified.
I'm looking forward to receiving your Phase 2 material,
with best regards,
Sabine
****************************
Sabine Mengel
ESO - User Support Department
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
For target MOA-197-XXX we supply our own photometric standard OB CAL_MOA-197
since the non standard readout FNS-HS is used for this target.
The calibrator is cataloged in Persson as S279-F-9172 (also in NACO OT queue for
standards) and
is about 12.5 in J, 12.1 (H) and 12.0 in K and of spec.type GOV.
The closer in time the photometric standards are taken (ideally right before or
after the
science), the better for the accuracy of the photometric calibration.
The other two targets (O-349 and MOA-192) are in in standard DCR-HD readout mode.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you have PSF reference star OBs, do the names of those OBs begin with
PSF_ ?
If there are Finding Charts attached to your OBs, is the field-of-view
of at least one of these charts 2' x 2' (with clearly labelled field orientation)
?
Have you clearly marked and labelled your wavefront reference objects
R1, R2, R3, ... (as specified in the NAOS Preparation Software) on your Finding
Charts ?
Have you specified the magnitude of the brightest object in the field-of-view
for each OB ?
Are there objects in any of your fields (including standard stars) which
are brighter than the limits specified in the User Manual and on NACO web Pages
?
If the previous answer is yes, have you given a list of OBs and a justification
for the brightness limit violation in the general description field ?
Last creation of page: Tue Oct 6 15:40:24 2009