README web version of /home/usg/OPS/MTS/readme_xml/readme_81030000
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
These 4 OBs (science + calibrator star) aim to monitor the physical behavior
of the Cepheid X Sgr. We need 4 measurements. The time resquested is then 1.5h*4=6h.
Using high-resolution mode in the K band with FINITO, we focus on the brackett gamma
2.1655, SiI 2.1777, SiI 2.1822, SiI 2.1879 spectral lines (in micrometers). We need
simultaneous CRIRES observation (the same night) in order contrain our Cepheid model
(see 081.D-0300(B)).
X Sgr is an atypical Cepheid which is not well known. Its mean angular diameter
is theta=1.47+-0.03mas, but its angular diameter variation has never been derived
by interferometry (even if it is supposed to be quite low, i.e. less than the typical
10% of Cepheids). Similarly, its H and K bands variation curves are not well establihed,
and even its mean magnitudes are not precise at all : H = 2.575 +- 0.196 and K =
2.499 +- 0.264. To detect the shockwave in the atmosphere of the star, we need the
longuest baseline A0-K0 (128m). In the four science OBs, we use the average value
of the angular diameter, and the K and H magnitudes, to provide the minimum visibilities.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
The period of the star is short P=7.7.01281 days (around one week). There
are also differences from one cycle to the other which are not clearly established.
We need 4 measurements corresponding to any random 4 nights during the ESO period.
Important : simultaneous CRIRES observations (same night as AMBER observations)
are required to obtain high-spectral resolution observations of BrG and metallic
lines studied (see 081.D-0300(B)).
Please, do not consider the "User comment" section in the OBs - in which we indicate
we need consecutive nights -.
Special Execution Requirements
Special Calibration Information
Using the Calvin tool we found the following calibrator, which is suitable
for our scientific purpose:
name : hd181109
V mag. : 6.57
K mag. : 1.95
Sp Type : M0III
UD : 1.62 +- 0.02 mas
source of diameter estimate : Borde et al. 2002, A&A, 393, 183B
We have chosen the science star (X Sgr) as a guide star.
In V band the mean magnitude of X Sgr is 4.63, and the expected variability is from
4.27 to 4.87.
The V amplitude is 0.6 (Moffett et al., 1984, ApJS, 55, 389).
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:24 2009
If you have comments, please contact usd-help@eso.org