README web version of /home/usg/OPS/MTS/readme_xml/readme_81022804
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
MIDI observations to probe the MOLsphere and the dust formation zone of
the non-Mira M giant BK Vir, for which our AMBER GTO observations are also approved
for P81. Our aim is to derive the physical properties of the molecular gas and
the innermost region of the dust shell from the MIDI+AMBER observations and to obtain
new insights into the mass loss mechanism in usual(non-Mira-type) AGB stars. Although
the variability of BK Vir is
smaller than that of Mira stars, it is preferable to execute all runs (381.D-0228A/B/C/D/E)
and our AMBER GTO program (081.D-0233A) as close in time as possible, in order to
avoid possible temporal variations.
Acqusition images should also be obtained both for the science target and the calibrators
for the following reasons: 1) the science target may turn out to be much more extended
than currently modeled. 2) Individual chopped frames in an acquisition image data
set (i.e., a movie of sky-subtracted frames) provide us with information on the
image quality and residual image motion, which is valuable for assessing systematic
errors in the observed visibilities. Therefore, acqusition images should be obtained
not only for the science target but also for the calibrators.
The number of frames for photometric exposures can be changed by the night-time
astronomer, depending on the actual brightness of the source
(whether it is the science target or a calibrator) as well as the atmospheric conditions.
No finding chart is attached for HD89484, because it is so bright that the 5x5 arcmin
area around it appears totally saturated in the optical image.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
We request two calibrator measurements in the CAL/SCI/CAL sequence. We
prepared OBs for two calibrators, HD89484 and tet Cen. It is preferable to observe
different calibrators before and after the science target (i.e., HD89484--SCI--tet
Cen or tet Cen--SCI--HD89484), but it is also acceptable to observe the same calibrator
before and after the science target, if one of them is not observable. For this
reason, two OBs for each calibrator is prepared.
Name : HD89484
Coordinates: 10:19:58.427 +19:50:28.53
V mag : 2.1
N mag : -1.2
Sp. Type : K1IIIb
UD diameter: 7.7 +/- 0.3 mas
Source : CHARM2
Name : tet Cen
Coordinates: 14:06:40.949 -36:22:11.84
V mag : 2.1
N mag : -0.76
Sp. Type : K0III
UD diameter: 5.3 +/- 0.06 mas
Source : CHARM2
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:23 2009
If you have comments, please contact usd-help@eso.org