README web version of /home/usg/OPS/MTS/readme_xml/readme_81019801
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
MIDI GTO observations of bright AGB stars. Targets are typically brighter
than calibrators, but more resolved. The program is aimed at monitoring a number
of cool stars. We anticipate that some of the observations cannot be carried out
within the time constraints - this should not have any influence on the others.
/ About the variability of the stars: (HIP, Combined General Catalogue of Variable
Stars) 30 Psc = Vmag variable with an amplitude between 0.06-0.6 mag / Alpha Hya
= Vmag variable with an amplitude < 0.06 mag / V Hya = Vmag variable between
9.0 - 6.5 V mag; Epoch for maximum light: 2430920. JD; Period 530.7 days
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Two epochs are foreseen for R Hya and W Hya. The exact date of the observations
is not critical, but OBs SCI_RHya_2,_3 and SCI_WHya_2,_3 should be executed at least
one month after OBs SCI_RHya_0,_1 and SCI_WHya_0,_1.
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:23 2009
If you have comments, please contact usd-help@eso.org