README web version of /home/usg/OPS/MTS/readme_xml/readme_81013502
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
These ISAAC OBs are aimed at getting a spectrum of a GRB afterglow in
the J+H band,
in particular the red part of Ly alpha, or (if the afterglow is too faint) to
map the SED with narrow-band filter imaging.
It will be triggered only if the redshift of the GRB is larger than about 5, and
the brightness of the afterglow is brighter than 18th (for spectroscopy) or
22nd (for imaging) magnitude, respectively.
ima NB1.19 NB1.26 H ISAAC_NB_10
ima Js NB1.64 NB1.71 Ks ISAAC_NB_13
ima H NB2.07 NB2.25 ISAAC_NB_15
ima Js H Ks ISAAC_JHK
spec LR 1.25 micron 200*1*6 sec J ISAAC_J_LR_1hr
spec LR 1.65 micron 200*1*6 sec H ISAAC_H_LR_1hr
spec LR 2.2 micron 200*1*6 sec Ks ISAAC_K_LR_1hr
spec MR 1.072 micron 600*1*3 sec J1 ISAAC_J1_MR_1hr
spec MR 1.130 micron 600*1*3 sec J2 ISAAC_J2_MR_1hr
spec MR 1.188 micron 600*1*3 sec J3 ISAAC_J3_MR_1hr
spec MR 1.246 micron 600*1*3 sec J4 ISAAC_J4_MR_1hr
spec MR 1.304 micron 600*1*3 sec J5 ISAAC_J5_MR_1hr
spec MR 1.57 micron 600*1*3 sec H1 ISAAC_H1_MR_1hr
spec MR 1.65 micron 600*1*3 sec H2 ISAAC_H2_MR_1hr
spec MR 1.73 micron 600*1*3 sec H3 ISAAC_H3_MR_1hr
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates ?
If you are using a specific offset pattern or position angle, did you
check carefully the definition in the manual ?
If you are doing spectroscopy, did you draw the slit on the Finding Charts
?
Did you enter the magnitude of the brightest star in the field-of-view
in the 'Instrument Comments' field of each OB ?
If you use the MoveToPixel acquisition, have you given clear instructions
on the FC and in the OB comment section as to how the field should be centered ?