README web version of /home/usg/OPS/MTS/readme_xml/readme_81009900
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
NIR NB multi-wavelength imaging of Milky Way nuclear star cluster in order
to examine its structure, measure extinction, classify the stellar population, and
search for young stars.
Please note the large offset (670 W, 380 N) required in order to obtain a good sky
backgroudn estimate on an empty field.
There are a few stars with K-magnitudes brighter than 8. Please see granted waiver
request.
For OBs with user priority higher than 10, the user priority is indicated in the
"user comments" field.
Waiver Requests
Waiver Request: 081.B-0099B.01
Please be informed that your waiver request to observe ISAAC
fields that contain stars brighter than the allowed limit was
granted. However, please note that the DIT should not exceed 5s.
Also note the waiver is granted under the restrictions that
the OBs must be executed at the end of the night or just before an
instrument change, in order to avoid any effect on subsequent
ISAAC observations.
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates ?
If you are using a specific offset pattern or position angle, did you
check carefully the definition in the manual ?
If you are doing spectroscopy, did you draw the slit on the Finding Charts
?
Did you enter the magnitude of the brightest star in the field-of-view
in the 'Instrument Comments' field of each OB ?
If you use the MoveToPixel acquisition, have you given clear instructions
on the FC and in the OB comment section as to how the field should be centered ?
Last creation of page: Tue Oct 6 15:40:23 2009
If you have comments, please contact usd-help@eso.org