README web version of /home/usg/OPS/MTS/readme_xml/readme_80500507
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
README for CenA observations
General remarks:
The object to observe is the circum-nuclear region in CenA in J-, H-, and K-band.
We want to get deep images on the star clusters close to the AGN, detected in our
medium-depth K-band image, which I attached for your reference (K-clumps_with_jet.jpg).
Moreover, I attached a finding chart for Cen A, and the according sky exposure (Finding_CenA.jpg).
The brightest object in the field of view is the nucleus/AGN of Centaurus A. It
has a magnitude 10.6 in K-band, 13.5 in H-band, and 15.2 in J-band.
The priority list for this run is:
1. K-Band imaging
2. J-Band imaging
3. H-Band imaging
Choice of AO-reference - PARSEC:
The observations should be taken with the Laser Guide Star.
Choice of tip-tilt reference:
The tip-tilt star given in the aocfg file is marked as R1 in the FC.
It was identified from the 2MASS point source catalogue (2MASS13252384-4300537)
and has a J-band magnitude of 9.9.
The time:
We have a total of 4 hours to observe CenA.
The OBs are designed to get approx. equal total on-source exposure times of ~30
min per filter. The DIT is chosen according to the two constraints:
1) not to saturate the detector with the bright AGN (especially in K-band 10.6 mag)
2) get enough flux from the extended emission (i.e. the clusters that we want to
see) to be above the background/read-out-noise
!!! We are interested in the stellar light around the AGN, not the AGN itself! If
the AGN is above the linearity limit or even marginally saturated, it's fine...
as long as it does not affect the quality of the images. If necessary, please adjust
the DIT accordingly.
The choice of the camera:
We chose to use the S27 camera for all filters. The K-band will be Nyquist-sampled
in the diffraction limit, while H- and J-band will be slightly undersampled. However,
in previous runs we experienced that in H- and J-band we could not reach the diffraction
limit. Moreover, we want to take advantage from the larger field of view of S27.
The observing strategy:
The acquisition for all filters is done in K-band, since the nucleus is best visible
in this band. Please move the AGN to a central position on the detector. For the
science template we chose NACO_img_obs_GenericOffset and we jitter the object on
5 positions on the detector to remove bad pixels and cosmics. In order to remove
the sky background, we plan to take sky exposures (S) in beween two object (O) exposures,
i.e. observe a sequence "OSO". Since Cen A fills a large area on the sky we need
a telescope offset of ~8.5' to get clear sky exposures. The position of the sky
exposure is fixed in the template. When taking sky exposures we only jitter on two
positions. Could you please make sure that these two sky fields do not contain very
bright stars, and if necessary offset them accordingly.
The priority list:
1. K-Band imaging
2. J-Band imaging
3. H-Band imaging
Please use PARSEC as AO reference, and put it as close as possible to the nucleus
of CenA, in order to get the best possible AO correction close to the centre.
CenA-K - DIT=15s, NDIT=1, #NEXPO=4, #OFFSETS=5
Please adjust the DIT according to the above mentioned criteria.
The total on-source integration time should be about 30 min. So, the OSO sequence
should be repeated 3 times
CenA-J - DIT=75s, NDIT=1, #NEXPO=1, #OFFSETS=5
Repeat 2 times, i.e. OSO OSO
CenA-H - DIT=30s, NDIT=1, #NEXPO=2, #OFFSETS=5
Repeat 3 times, i.e. OSO OSO OSO
I have prepared two OBs: one for K-band and one for J- and H-band, where the filter
is changed in the middle of the OB. The execution time is ~1hr51min for the first
one and 2hr4min for the second one. I have a waiver approved that allows OBs with
a total execution time of more than 1h (this waiver request was submitted and approved
on Sep 9, 2008).
Thanks a lot for carrying out the observations and best of luck!!!
Nadine Neumayer (nneumaye@eso.org)
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you have PSF reference star OBs, do the names of those OBs begin with
PSF_ ?
If there are Finding Charts attached to your OBs, is the field-of-view
of at least one of these charts 2' x 2' (with clearly labelled field orientation)
?
Have you clearly marked and labelled your wavefront reference objects
R1, R2, R3, ... (as specified in the NAOS Preparation Software) on your Finding
Charts ?
Have you specified the magnitude of the brightest object in the field-of-view
for each OB ?
Are there objects in any of your fields (including standard stars) which
are brighter than the limits specified in the User Manual and on NACO web Pages
?
If the previous answer is yes, have you given a list of OBs and a justification
for the brightness limit violation in the general description field ?
Last creation of page: Tue Oct 6 15:40:22 2009
If you have comments, please contact usd-help@eso.org