README web version of /home/usg/OPS/MTS/readme_xml/readme_80035101
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
We would like to observe the spectroscopic binary BS_Indi with AMBER.
The two components have an average separation of 40 mas, and can thus be resolved
with AMBER. BS_Indi has a magnitude in the K band of 6.6, it thus has to be considered
a rather faint object for AMBER, quite close to the limiting magnitude of the instrument.
Thus in order to detect the fringes it is presumably necessary to use an integration
time of 50 msec. Thus, please carry out the observation with this integration time
long enough to detect the fringes. With the standard integration time of 25 msec
it will presumably not be possible detect the fringes. Since it is not possible
to specify the correlation time in the proposal but only the seeing, we asked for
0.8 arcsec seeing for BS Indi, because under good seeing conditions the
correlation time is usually also long. Thus, we ACTUALLY DO NOT NEED 0.8 arcsec
seeing, we simply need wheather conditions that are good enough to detect fringes.
See "Special Calibration Information" for informations about our calibrator HD207043.
Waiver Requests
Critical Observing Condition Constraints
As pointed out above, with a K-magnitude of 6.6 this star has to be considered
as faint for AMBER. It is thus presumbly necessary to use an integration time of
50 msec for detecting the fringes. Since long correlation times usually come with
good seeing conditions, we requested a seeing of <= 0.8 arcsec. However, we actually
do not need 0.8 arcsec. What we really need are wheather conditions that allow to
detect the fringes of BS Indi. The observation can
be done also under worse weather and seeing conditions, as long as fringes are detected.
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
The visibility calibrator choosed (HD207043) is not in the CalVinc database.
HD207043 has a magnitude in the K band of 6.05, it is a G5V
star and it is located at a distance of 34 pc. The angular diameter of the star,
assuming a physical solar diameter given the spectral class, should be 0.27mas.
The star is not resolved by the choosed baseline configuration and we think than
we can use it as a calibrator comparing the observed visibility to that one of a
point source.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:21 2009
If you have comments, please contact usd-help@eso.org