README web version of /home/usg/OPS/MTS/readme_xml/readme_80034700
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
The objective of this run is to obtain high resolution, high signal-to-noise
(>400) spectra of stars which will be used for benchmark tests of synthetic
spectra and stellar atmosphere models.
Most of the targets (18) are brighter than V=7 and no bright
companions are in the HARPS field of view. The observations for these
stars are executed in one OB. No finding charts have been attached for these
stars. Please note the Special Execution Requirements for bright stars.
Three stars are fainter than V=7. These observations require several OBs,
which will be co-added to achieve the required S/N. See Special Execution
Requirements for faint stars. Finding charts have been attached for these stars.
We request standard calibrations for all stars.
For nine stars we request the observation of a spectrophotometric
standard in the same night at a similar airmass, if possible, but not more
than three standards per night.
These stars are K and M stars (with Teff <= 4500K), for which the standards
will be used to determine the continuum level.
This request has been added to the OBs for these stars under "Calibration Requirements".
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
1) Bright stars (V<7)
The exposure times have been calculated for a Seeing of 1.2 arcsec, to achieve
maximum possible S/N. If the seeing is smaller than 1.0 arcsec, please choose
a lower exposure time in order to avoid saturation of the CCDs.
2) Faint stars (V>7)
For three targets, there are several OBs. These data will be co-added to
achieve the required S/N.
Preference should be given to the completion of all the OBs on the same
target, before proceeding with another target.
The targets are HD 84937 (4 OBs), HD 113083 (3 OBs), HD 140283 (2 OBs).
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Last creation of page: Tue Oct 6 15:40:21 2009
If you have comments, please contact usd-help@eso.org