README web version of /home/usg/OPS/MTS/readme_xml/readme_80017000
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
The purpose of this run is to obtain circular spectropolarimetry of the
extremely magnetic Ap star HD 75049 at 12 epochs spread across Period 80 so as to
determine its rotation period, and to characterise the variations of its mean longitudinal
magnetic field with this period. In order to achieve these objectives, it is essential
that the epochs of execution of the different OBs be distributed in a fairly even
manner over most of the period. Exact time intervals between two consecutive epochs
of observations are unimportant, but too short intervals, as well as the accumulation
of a significant fraction of the observing epochs over a short fraction of the semester
should be avoided. As a rule, the time interval between two consecutive epochs of
observations should be longer than a week; as an exception, a single pair of OBs
(out of the total of 12) mutually separated by only 2-3 days (but separated from
any other OB by more than a week) would be acceptable, and might possibly even be
useful.
Waiver Requests
080.D-0170A.01.WAV, submitted Sep 3, 2007; granted Sep 6, 2007: non-standard
readout mode 200kHz,1x1,low
Critical Observing Condition Constraints
Time-Critical Aspects
It is essential that the epochs of execution of the different OBs be distributed
in a fairly even manner over most of the period. Exact time intervals between two
consecutive epochs of observations are unimportant, but too short intervals, as
well as the accumulation of a significant fraction of the observing epochs over
a short fraction of the semester should be avoided. As a rule, the time interval
between two consecutive epochs of observations should be longer than a week; as
an exception, a single pair of OBs (out of the total of 12) mutually separated by
only 2-3 days (but separated from any other OB by more than a week) would be acceptable,
and might possibly even be useful.
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you have prepared your finding charts with tools other than FIMS,
do they comply with the specifications on the FORS1 Phase 2 web page ?
Last creation of page: Tue Oct 6 15:40:20 2009
If you have comments, please contact usd-help@eso.org