README web version of /home/usg/OPS/MTS/readme_xml/readme_80014000
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This is a UVES high-resolution survey in a volume-limited sample of late
M dwarfs.
All targets are of spectral type M7-M9.5 and within 20pc. Proper motions (PM) can
be very large and is given when available. For some objects, it is not known, but
the objects are relatively bright in I and should be easy to find using the finding
charts.
One observation is planned per object, exposure times are split into three exposures
when the integration time is longer than 15 minutes. Observations can be carried
out any time.
One telluric standard star is added, this OB may also be carried out at any time
(not necessarily before or after any other OB).
In one case, 2MASS0024, the system consists of at least three components, the two
main components (A and BC) should be distinguishable from each other. If possible,
it would be helpful if both targets were put in the slit. For this OB, derotation
mode is put to SKY so that one can align the components in the slit (the direction
should be obvious from the slit viewer).
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you specified the S/N ratio at given wavelength in the User Comments
field of each OB?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you need secondary guiding, are there suitable objects within 30 arcsec
from your target ?
Last creation of page: Tue Oct 6 15:40:20 2009
If you have comments, please contact usd-help@eso.org