README web version of /home/usg/OPS/MTS/readme_xml/readme_80011000
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This run targets galaxies in the field of a z=3.1 protocluster using FORS2
multi-object spectroscopy with masks (FORS2 MXU mode). The galaxies were selected
to have a high probability to be at a redshift of the protocluster.
Because of the faintness of the targets, we would like to observe one mask for the
9 hours of allocated time. This means that the mask used in all of the OBs is the
same mask. The mask targets 32 candidate high redshift galaxies. In addition, 8
(bright) stars are placed in the mask (using boxes with sizes 3"x3"-4"x4") to check
the centering of the mask in the through slit image.
To prepare the mask, an I band image taken with FORS2 in September 2002 was used.
For the image acquisition, 10 reference stars were selected with (Vega) magnitudes
in the I band in the range 18-21.8. On the finding charts these reference stars
are marked by a circle. To check the alignment of the mask, 8 stars are placed in
the mask, most of them (6) will fall on the master (top) CCD. On the finding charts
these alignment stars can be recognized by the square slit through which they are
observed.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you have prepared your finding charts with tools other than FIMS,
do they comply with the specifications on the FORS1 Phase 2 web page ?
Last creation of page: Tue Oct 6 15:40:20 2009
If you have comments, please contact usd-help@eso.org