README web version of /home/usg/OPS/MTS/readme_xml/readme_80010500
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Imaging of supernova SN 1987A.
Imaging should be straightforward. However, for posterior deconvolution and
estimates of limiting magnitudes, a close reference star (2MASSJ05355628-6917507)
will be imaged too
EACH TIME (PRIOR OR AFTER) an OB is executed for SN1987A in the PAH filter.
We would like to get OB302246, OB302248 and OB288617 executed consecutively during
the same night, if possible. Would this be impossible, OB 288617 should be executed
without accompanying PSF.
NO PSF measurements are required for the Q2 filter.
Finding charts are provided from the visible to the near-IR light only, as no usable
10 micron
image is available. Although they should not be really needed for imaging for which
a blind pointing
should be accurate enough, they can be used for all the OBs.
- FC1: 3'x3' V band image with a few identifications and corresponding coordinates.
- FC3: 4.5'x4.4' I band image of the field comprising the three stars of interest
(SN, EQJ, REF)
- FC4: 4.4'x4.4' K band showing the 2 MACHOS objects in the field which will be
imaged
(REF and EQJ), while the supernova complex is NOT seen at this wavelength.
- FC5: 45"x45" HST image showing the close environment of the supernova. This image
comes
from the HST Gallery and has the spatial resolution necessary for separating the
two brighest companions (stars S2, S3) and the equatorial ring which should be resolved
with
VISIR.
PLEASE NOTE that due to the faintness of the object it is very important that the
four
beams for both SN1987A (and 2MASSJ0535) be usable on the chip.
Good luck and thanks a lot in advance!
Waiver Requests
The IR signal from the supernova is very weak and we might not see it
(indeed, we didn't see
it during our observations in period 78). On an other hand, the field will be absolutely
empty and thus recentering/merging of separate frames would be venturous. We need
thus
to get a minimum of 1 hour continued integration. That translates into 1h39min for
the imaging OB.
We therefore requested that these long OBs be allowed, which was accepted.
Critical Observing Condition Constraints
As usual thermal IR observations require dry AND STABLE conditions.
Further, due to the high spatial resolution required for our program,
and the very low flux level to be detected, we DO need to be
diffraction-limited at 10 micron and we request the
HIGHEST QUALITY ATMOSPHERIC CONDITIONS (= BETTER THAN EXCELLENT).
We stress that observing under less than excellent conditions would
be a waste of telescope time.
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
No special photometric calibrations are requested. Note however taht,
as stressed in the "Special Execution Requirements", that the PSF star EQJ0535 must
be imaged for each OB of SN1987A through the PAH filter.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If the provided finding chart is at a different wavelength than the observations,
did you clearly describe in the README file how to identify the target?
Did you specify a guide star brighter than V=12mag within a field of
r=5arcmin around the science target?
Last creation of page: Tue Oct 6 15:40:20 2009
If you have comments, please contact usd-help@eso.org