README web version of /home/usg/OPS/MTS/readme_xml/readme_79066801
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This project aims at the identification of infrared counterparts (OB and
Be emission-line stars) to obscured High Mass X-Ray Binaries in the region of the
Galactic Arms. OBs are organized by priority, as specified in each "User Priority"
field. We submitted OBs for standard stars since we need a very accurate removal
of telluric features (see Special Calibration Information for details).
We intend to obtain snr ~ 100.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
We submitted two OBs for calibration per scientific target. They both
correspond to telluric standard stars and we need them in order to ensure accurate
removal of telluric features. We recommend to observe the two provided calibration
OBs contiguously to the corresponding science target, as also reported in the ?User
Comments? field of each science OB. This means we would prefer the execution of
the two calibration OBs, one before and one after the scientific OB. That would
ensure minimal airmass differences between the standard and the science target.
We summerize in the followong table the correspondence between science and calibration
OBs:
Science OB | cal. OB 1 | cal. OB 2 |
| | |
IGRJ16358 | HIP81229_1 | HIP80032 |
IGRJ16493 | HIP80982 | HIP81949_1 |
IGRJ16393 | HIP81949_2 | HIP81229_2 |
Here we provide magnitude and spectral type of supplied standard stars:
HIP81229: K = 7.046 mag, G3V star
HIP80032: K = 7.745 mag, A0V star
HIP80982: K = 7.283 mag, G2V star
HIP81949: K = 7.388 mag, A3V star
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates ?
If you are using a specific offset pattern or position angle, did you
check carefully the definition in the manual ?
If you are doing spectroscopy, did you draw the slit on the Finding Charts
?
Did you enter the magnitude of the brightest star in the field-of-view
in the 'Instrument Comments' field of each OB ?
If you use the MoveToPixel acquisition, have you given clear instructions
on the FC and in the OB comment section as to how the field should be centered ?
Last creation of page: Tue Oct 6 15:40:19 2009
If you have comments, please contact usd-help@eso.org