README web version of /home/usg/OPS/MTS/readme_xml/readme_78020000
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
We will perform near-infrared spectroscopy of selected intermediate-mass
stars, which exhibit strong H_alpha emission in known star forming regions in the
Large Magellanic Cloud (LMC). The aim of this observing run is to verify the pre-main
sequence nature of these stars. This study has the potential to provide an original
characterization of candidate Herbig Ae/Be stars through their near-IR spectral
features, such as circumstellar shells, and the first solid discovery of such stars
in the low-metallicity environment of the LMC. Our observing strategy is to perform
SINFONI spectroscopy in the K- and H-band for three targets, selected as the most
promising candidates, based on their H_alpha excess found earlier with ground-based
photometry, and on recent high-resolution HST/ACS imaging. For one of the targets
spectroscopy in the J-band will be also performed. The NIR magnitudes for our selected
targets according to the 2MASS All-Sky Point-Sources Catalog are: Star #37: J=14.94
mag, H=14.97 mag, K=14.99 mag. Star #157: J=15.46 mag, H=15.03 mag, K=14.57 mag.
Star #194: J=15.53 mag, H=15.02 mag, K=14.85 mag.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate the magnitude of the brightest object in the field in
each SINFONI OB?
If you are using the AO: Did you indicate for every OB the magnitude
of the guide star, and its distance to the target (if any)?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates?
If you are using a specific offset pattern or position angle: did you
check carefully the definition in the manual?
Did you make really sure that none of your OBs ever saturates the detector?
If you are using the AO: did you enter the correct Strehl Ratio (on-axis,
K-band) AND the seeing value in the constraint set?
Last creation of page: Tue Oct 6 15:40:15 2009
If you have comments, please contact usd-help@eso.org