README web version of /home/usg/OPS/MTS/readme_xml/readme_76502500
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Low resolution spectroscopy (8.5 and 12.4 mu) of three young targets with
circusmtellar
matter. Two targets will be placed within the slit and observed simultaneously (OBs:
170*).
The third target is a single object but we have defined a rotator angle to include
its extended
emission within the slit (OBs: 177*).
The most critical parts of the program are:
(i) the acquisition, since the targets are faint
(ii) the chop throw: for two OBs (pr170*) it MUST BE CHANGED
TO 6" by the Night Astronomer. Please, CHECK the Special Execution requirements!!
Waiver Requests
1 Waiver submitted 276.C-5025A.01 on 13/01/06 to use a chop throw of 6".
Accepted on 23/01/06 under these conditions:
- The OBs must contain the same guide star and observational parameters
(rot.offangle and chop.posang) used in previous observations, in order
to avoid the overlap of the two autoguider boxes.
WE have used the requested values in the submitted OBs: pr170_337_8 and pr170_337_12.
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
OBs pr170_337_*:
Two targets must be placed within the slit (the brighter one in the center).
The finding chart shows the VISIR acquisition image obtained last year with the
two sources.
Look for the bright reference stars (marked as ref 1 and ref2 in the finding chart)
to identify the targets.
!!!!!!!!!!IMPORTANT!!!!!!!
-->NOTE TO THE Night Astronomer: A WAIVER HAS BEEN GRANTED TO CHANGE THE CHOP
THROW TO 6" IN THE OBs pr170_337_12 and pr170_337_8. Please, change it MANUALLY.
--> NOTE to the TIO: We have chosen a guide star that worked fine in previous
observations. Please, set the guide probe orientation (positive or negative (=alternate))
to ensure that the boxes do not overlap.
OBs pr177_*:
Long acquisitions (3 minutes)
Two Finding charts are provided:
FC1: VISIR PAH1/SF deep image of the target showing the extended tail to be placed
within the slit.
FC2: VISIR/N_SW acquisition image with the expected position of the target.
We have submitted two OBs per setup with two different chop throws (10" and 11").
It would be great if you could execute the 2 OBs consecutively but this is not critical.
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If the provided finding chart is at a different wavelength than the observations,
did you clearly describe in the README file how to identify the target?
Did you specify a guide star brighter than V=12mag within a field of
r=5arcmin around the science target?
Last creation of page: Tue Oct 6 15:40:11 2009
If you have comments, please contact usd-help@eso.org