README web version of /home/usg/OPS/MTS/readme_xml/readme_76063700
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This program seeks to obtain IFU spectra of E+A galaxies selected from
the 2dF redshift survey. The objects are at z=~0.1 and thus rather small, e.g.,
10" across. In spectroscopy we estimate to detect an even smaller area, e.g., 3"
diameter. The VIMOS IFU is used with the HR_blue grism, and 0.33 arcsec sampling
giving a total FoV of 13"x13".
In total there are 8 different targets. For each target we have 2 OBs (1h31min total
execution time per OB) with slightly dithered positions. Only exception is E+A_8p76
with 3 OBs.
The RA of the targets will mainly determine the sequence of execution. In case of
multiple target availability we have assigned priorities ranging from 1-8. 1 has
the highest priority. Please always finish a set of OBs for one target before starting
another object.
The object location is indicated with a box corresponding to the FoV of VIMOS (13"x13")
on the finding charts.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify suitable guide stars for all your OBs using Guidecam
?
Did you check that the chosen guide stars are suitable for all the offset
positions and that they do not produce unacceptable vignetting of the field of view
?