README web version of /home/usg/OPS/MTS/readme_xml/readme_76053400
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
We want to determine the velocity despersion of the outer halo globular
cluster Pyxis. In order to do this we observe 28 red giants and red horizontal branch
stars in Pyxis. The observation is done in three set-ups: 'bright' for stars with
R<18.3, 'medium' for stars with R<18.7 and 'faint' for stars with R<18.8.
For each set-up seven stars are observed, the 'medium' set-up is performed twice.
The eighth UVES fibre is used for sky measurements.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
We would like to set the following priorities in executing the observations:
The three OBs "pyxis_bright*" should have the highest priority and should be executed
first. The OBs for "pyxis_medium_a*" have the second-highest priority and should
all be executed after "pyxis_bright*" is finished. The third-highest priority goes
to the OBs "pyxis_medium_b*". Lowest priority is awarded to the OBs of "pyxis_faint*".
Of course all of these observations are important, but we realize that it may not
be feasible to execute all of them. Hence we propose priorities in the sequence
of the magnitudes of the stars.
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify in your OBs the hour angle range for which your Target
Setup files are valid ?
Did you specify in your OBs the magnitudes of FACBs and Guide Star for
all your fields ?
Are the FACBs and Guide Star in the brightness ranges specified in the
FLAMES manual ?
Did you enter the expected signal to noise in your OBs ?
Last creation of page: Tue Oct 6 15:40:10 2009
If you have comments, please contact usd-help@eso.org