README web version of /home/usg/OPS/MTS/readme_xml/readme_76052400
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Radial velocity measurements of 6 low-mass spectroscopic binaries in the
ONC region.
There are two type of OBs:
g1_u1 and g1_u2 - Giraffe targets are the same in both groups, only UVES targets
change. So please do not execute more than one OB of this program per night.
The guide star chosen is close the lower magnitude limit of R=13. If needed the
night astronomer can use one of the other 2 potential GSs given in the .ins file
with the guide probe position set to "NEG"
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Please, do not execute more than one OB of *this program* per night.
Since all OBs (ONC_g1_u1 or ONC_g1_u2) have the same giraffe targets, executing
an ONC_g1_u1 and an ONC_g1_u2 at the same night *is not* allowed either (this means
that I'll have more than one radial velocities point almost at the same orbital
phase!).
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you specify in your OBs the hour angle range for which your Target
Setup files are valid ?
Did you specify in your OBs the magnitudes of FACBs and Guide Star for
all your fields ?
Are the FACBs and Guide Star in the brightness ranges specified in the
FLAMES manual ?
Did you enter the expected signal to noise in your OBs ?
Last creation of page: Tue Oct 6 15:40:10 2009
If you have comments, please contact usd-help@eso.org