README web version of /home/usg/OPS/MTS/readme_xml/readme_76029600
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
We want two SOFI spectra (H-and J-band) of line emission from a linear
string of knots in the Helix Planetary Nebula, headed by a knot known as Knot 38.
The finding chart, a 10-sec SOFI image taken with the NB_H2_S1 filter shows knot
38 and the linear feature extending to the left (North-East) and the desired position
of the slit. We have specified a 200s acq. image with the same filter, so the feature
should be clear. In the initial ON position on the slit, the knot should be positioned
about 3/4 down the slit, toward the Southern end. PA of slit on sky is 41deg;equals
Rotation Offset on sky? Because there is emission everywhere in the nebula (see
finding chart) the OFF position in the nodding along the slit must be at least 7'
from the ON position. We have specified 420" as the nod length and combined offset=T.
If guiding is not possible with this throw length then the observation should be
done with tracking only. In the K-band spectra we are interested in the ratio of
the 1-0S0,1 and 2 lines at 2.22,2.12 and 2.03 mu and 2-1S3 at 2.07 mu, and Pa-Beta:1.28mu
in the J-band (Pa-alpha in in a sky absorption hole and Br-gamma is very weak in
this source. cf. 76.C-0296(B)
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Last creation of page: Tue Oct 6 15:40:09 2009
If you have comments, please contact usd-help@eso.org