README web version of /home/usg/OPS/MTS/readme_xml/readme_76011800
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
Optical spectroscopy of the optical counterpart of the bright X-ray source
in the circinus galaxy.
We have identified a faint source in FORS V and I band imaging and want low resolution
spectra
of the source to determine its nature. Acquisition of the target should be done
as follows:
In order to be sure of locating the faint source in this crowded inner galaxy region,
we would
like the slit aligned with two bright sources which will be easy to identify. The
target falls
between these two, exactly along their alignment. We will use a 2" slit to be sure
of getting all
the flux in the slit. We have estimated the PA of the slit to be 55 degrees East
of North and
have specified that in the OBs. The through slit image should be used to identify
the two
acquisition stars (marked on the zoom finding chart) and the slit sligned with these.
We used this strategy in Period 74 to observe the target and it was successful -
although
our OBs were not completed.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you have prepared your finding charts with tools other than FIMS,
do they comply with the specifications on the FORS1 Phase 2 web page ?
Last creation of page: Tue Oct 6 15:40:09 2009
If you have comments, please contact usd-help@eso.org