README web version of /home/usg/OPS/MTS/readme_xml/readme_75038400
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This programme will obtain L- and M-band spectroscopy toward embedded
and background stars associated with two dense molecular cores (L310 and SVS4).
The main goal is to map the abundance of CO ice in the two cores. Central to the
execution of the programme is that the instrument is rotated to allow two sources
in the slit for each pointing. The OBs are supplied with approximately correct position
angles, but the rotation may have to be refined according to the finding charts
in order to properly include two requested targets in the slit.
L310 will be observed in the L- and M-band with 4 pointings each, and SVS4 only
in the M-band with 4 pointings.
Three pointings for the faintest sources (2 for SVS4 and one for L310) have each
been split into two independent set of OBs
(science + standard) in order to obtain longer on-source integration times.
Because the SVS4 targets are all located within a field only 30 arcseconds across,
all OB positions for this core are set to a single central position. The L310 targets
are spread over a larger region, and therefore the OB positions for this core are
set to the central position between the two targets of a given pointing.
Waiver Requests
A waiver request with the Id 75.C-0384A.01.WAV was submitted on February
4, 2005, and approved on February 9 and February 11, 2005.
This waiver request concerned the rule stating that the total execution time for
an OB cannot exceed 1 hour. We got the permission to extend the execution time for
these OBs to 1 hour 15 minutes.
Further we got permission to change one source of our source list.
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
The spectra require the observation of telluric standard stars either
just before or after the science observations. We prefer that the standard is observed
within 0.1 airmass of the source, although a somewhat worse
airmass difference (<0.15) should not prohibit the execution of an OB.
The calibration star for L310 in the M-band is BS7121 (Type: B2V; Magnitude: 2.8).
For L310 in the L-band the calibration star is BS6700 (Type: B9V; Magnitude: 4.9).
The calibration star for SVS4 in the M-band is HD177756 (Type: B9Vn; Magnitude:
3.5).
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
If you submitted OBs for standard stars, did you use the provided StandardStar
templates ?
If you are using a specific offset pattern or position angle, did you
check carefully the definition in the manual ?
If you are doing spectroscopy, did you draw the slit on the Finding Charts
?
Did you enter the magnitude of the brightest star in the field-of-view
in each OB ?
If you use the MoveToPixel acquisition, have you given clear instructions
on the FC and in the OB comment section as to how the field should be centered ?
Last creation of page: Tue Oct 6 15:40:07 2009
If you have comments, please contact usd-help@eso.org