README web version of /home/usg/OPS/MTS/readme_xml/readme_75006400
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
MIDI observations of the dusty, discoidal environments of 3 TTauStars.
This run A consists of 14 OBs, 7 for targets, 7 for calibrators.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
The scientific target HBC 639 is a binary with a Separation of 2.''2.
The position angle of the second companion is 150degree from North to East. The
optical and near-IR brighter (delta(H) = 1.9mag) component is here the first component.
Thus, the 2MASS-coordinates I provide for the coude giude star are the coordinates
of this first component. The second component is the brighter component in the mid-IR
(delta(L) = -0.5mag) and was the only component which could be observed by TIMMI2
(Przygodda et al. 2003) in Nband. Therefore, we want to observe this second component.
The scientific target SCrA is a binary (distance 1.''3, position angle 160degree).
The optical and infrared brighter (delta(H)=0.8mag, delta(L)=1.0mag) component should
be observed 3times (twice by UT2 - UT4 (this run) and once by UT3-UT4(->run B))
and the fainter component once (UT2-UT4 (this run)). For each observation block
of SCrA it is necessary to check where the companion is in order to observe the
correct object.
Special Calibration Information
The calibrators were chosen because of their proximity to the scientific
targets. All of them were selected from the CalVin list.
Calibrators are
HD152885(V=6.61mag,F12um = 12.6Jy,spect. type:M1 III,distance: 12.0deg.) for RU
Lup
HD142804(V=6.567mag,F12um = 11.7Jy,spect. type: M1 III,distance: 10.9deg.) for HBC
639
HD178345(V=4.117mag,F12um = 12.5Jy,spect. type: K0 II,distance: 3.0deg.) for SCrA.
Each calibrator should be observed right after the observation of the corresponding
scientific target.
The calibrators HD152885(->SCI_RULup) and HD142804(->SCI_HBC639) are more
distant than 5degrees to the corresponding scientific object. So the selected calibrator
could be not available at the time when the scientific target is visible. Thus,
we specify an alternative calibrator for the concerning targets in the USER COMMENT
Line and Calibration Requirements Folder of the OBs of the corresponding scientific
target without creating new OBs. But, of course, the Paranal Science Operations
should have the right to exchange these alternatively suggested calibrators if it
is necessary.
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'User Comments' field ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Last creation of page: Tue Oct 6 15:40:06 2009
If you have comments, please contact usd-help@eso.org