README web version of /home/usg/OPS/MTS/readme_xml/readme_60905322
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
This program aims for AMBER observations of AGN tori.
* NGC1068 is the highest priority target since it is the brightest object. NGC1365
is second priority and should be observed if NCG1068 is not feasible (AO may work
better for NGC1365). Two more objects are provided if it turns out that targets
for other hour angles are required.
* Even if observations of the primary targets NGC1068 and/or NGC1365 are not successful,
the other two provided targets can be tried if there
is time (correlated magnitudes are not well known, and they might be better suited
than expected)
* Each target is associated with 2 calibrators. Please first use the ones flagged
with "_1". If time is available, please use both calibrators to improve the calibration.
* OBs of the AGN contain 2MASS coordinates. In case fringes are not found, please
use the following Radio coordinates instead:
Object Radio RA Radio DC
----------------------------------------------
NGC 1068 02 42 40.724 -00 00 47.37
NGC 1365 03 33 36.35 -36 08 25.9
NGC 7469 23 03 16.616 +08 52 26.02
NGC 424 01 11 27.647 -38 05 00.72
* The coordinates of the NIR cores of AGN are not known with high precision. They
might be off by up to 0.5-1 arcsec, which
translates into an OPD uncertainty of 250-500 microns. To be on the safe side,
please search at least +/-1 mm plus the
residual uncertainty from the OPD model.
* If fringes are not detected by Finito, please try also with AMBER alone.
* If fringes are not detected in real-time by the system (neither Finito nor AMBER
alone), but MACAO and IRIS are guiding,
please record data blindly at the OPD offset found for the calibrators. The calibrators
are very close to the targets (a few degrees).
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:06 2009
If you have comments, please contact usd-help@eso.org