README web version of /home/usg/OPS/MTS/readme_xml/readme_60905310
Principal Investigator Email Address
Estimated Total Execution Time (hours, including overheads)
General Description
The aim of this programme is to measure the origin of the Brackett gamma-line
emission (2.1662 micron) in YSOs using AMBER's high-resolution mode (HR-2.172).
Please adjust the DIT according to the FINITO performance - our main aim is to measure
differential observables.
We suggest to start the observing sequence with SCI_TTAU and to try to find fringes
on this star.
If FINITO works sufficiently well to record HR-interferograms on TTauN, then we
suggest to follow the sequence:
1a.) SCI_TTAU
2a.) CAL_HD27429_TTAU
3a.) SCI_HD50138
4a.) CAL_HD52938_HD50138
If within 15min FINITO does not work sufficiently well on SCI_TTAU, then we recommend
to interrupt this target and follow this sequence:
1b.) SCI_HD50138
2b.) CAL_HD52938_HD50138
3b.) SCI_MWC147
4b.) CAL_HD46735_MWC147
The characteristics of our calibrator stars are as follows:
HD27429: H=5.2, K=5.2, F3, UD=0.39mas (CalVin), calibrator for TTAU
HD28930: H=3.8, K=3.7, G8, UD=0.91mas (CalVin), bright alternative calibrator for
TTAU
HD52938: H=4.1, K=3.9, K3, UD=0.87mas (CalVin), calibrator for HD50138
HD51054: H=3.8, K=3.7, K2, UD=0.91mas (CalVin), alternative calibrator for HD50138
HD50277: H=5.2, K=5.1, F0, UD=0.37mas (ASPRO), calibrator for MWC147
HD45415: H=3.3, K=3.2, G9, UD=1.06mas (CalVin), bright alternative calibrator for
MWC147
Besides the standard calibrators, we prepared for each object also OBs for some
alternative calibrators.
These alternative calibrators are significantly brighter than the science target,
and can therefore also be observed in case the atmospheric conditions decrease between
the science target observation and the calibrator.
TTAU is a close multiple system. Please center the AMBER fiber on the brightest
(northern) component (see also attached finding chart).
In case a filler object might be needed at the beginning of the night (LST<=21:28),
we prepared also OBs for the very bright Herbig Be star MWC297 (K=3.0, H=4.4) and
an associated calibrator.
Waiver Requests
Critical Observing Condition Constraints
Time-Critical Aspects
Special Execution Requirements
Special Calibration Information
ToO Information
ToO Activators List
Is this a Pre-imaging run ?
Pre-imaging Requirements
Source(s) of Pre-imaging
Pre-imaging sources not listed above
Do all your OBs comply with the instrument-specific requirements listed
on the instrument-specific Phase 2 web page ?
If this is a pre-imaging run, did you select PRE-IMAGING for the Observing
Category for each Observing Template ?
Do all your finding charts comply with both the general and instrument-specific
Phase 2 Web Pages ?
If you submitted OBs for standard stars, did you specify the magnitude
and spectral type of all standard stars in the OBs ?
Have you included OBs for any calibrations that you need but which are
not part of the Calibration Plan ?
If you are observing Moving Targets, have you attached suitable ephemeris
files to your OBs?
If you have preferences which OBs should be executed first, did you make
use of the User Priority field in the OBs ?
If this is a run that requires coordinated observations with other facilities,
did you give proper instructions in the Time-Critical Aspects Section ?
Did you indicate for each science star OB the corresponding calibrator
star OB (and vice versa) in the 'Instrument Comments' field ?
Did you check that your chosen calibrator is bright enough for the instrument
mode used ?
If you use calibrator stars which are not in the CalVin database, did
you specify their characteristics in the README file and in the OBs ?
Do you use the same DIT for pairs of science target and associated calibrator?
Are the magnitudes of science target and calibrator within +/- 1 mag
?
Did you verify that your coordinates are as accurate as possible (2Mass
coordinates recommended) and that they include proper motions if available ?
Did you specify the LST range of the calibrators such that they cover
the range from 30 min before the start of the LST range of the science target to
30 min after the end of the LST range of the science target ?
Last creation of page: Tue Oct 6 15:40:06 2009
If you have comments, please contact usd-help@eso.org