README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID: 71.D-0284(A) Principal Investigator Name: J. Simon Clark Principal Investigator E-mail Address: jsc@star.ucl.ac.uk Principal Investigator Telephone Number: +44 (0)207 679 4372 Principal Investigator Postal Address: Dr Simon Clark Dpt of Physics and Astronomy University College London Gower Street London WC1E 6BT England United Kingdom Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 3h Estimated Total Execution Time (including overheads): 3h README File Submission Date: 5 March 2003 Programme Description ===================== General Overview ---------------- This programme consists of imaging of the area of the open cluster Westerlund 1 (Wd 1) in the broad-band VRI filters. This field is very reddened. For this reason, most of the exposure time is dominated by the V-band exposure, which is very long. Also for this reason, it needs a standard field containing faint and red stars. I have not been able to find any nearby fields with those requisites. Therefore I have selected two subsets of Landolt's area 110, one of which happens to be one of FORS1 standard fields. This is approximately two hours (in RA) after the cluster. Since all objects are faint, dark sky is necessary and relatively low air masses are preferable (z<1.4). One standard field (LAN110-315) should be observed only once at approximately the same airmass as the cluster. The second standard field (LAN110-362) should be observed at three different airmasses, so as to obtain extinction points. These three observations could be intersparsed with those of the open cluster, but may be less relevant if the target may be observed in all filters close to the zenith. Needless to say, all observations must be carried out in one single night. The standard fields are above Z=1.5 for ~4 hours at the latitude of the observatory. The target is high for much longer. The field selected for extinction calibration is Landolt 110-362 (centred at the coordinates I give, there should be 7 standard stars in the field). This happens to be a FORS1 standard field. The other field selected for one single observation is Landolt 110-315 (5 standard stars). The two fields are VERY close in the sky, just a few arcminutes away. Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- As indicated, dark skies are absolutely necessary in order to reach sufficiently deep in the V-band exposures of the target field. In theory, requisits are not so strong for other bands, but the observing conditions force the whole programme to be carried out in dark time since it has to be done all in the same night and target has to be bracketed between standards. Since the cluster core is rather crowded, good seeing conditions are needed. We have selected 0.8" as an indication of this, but it is not a very strict constraint. Time Critical Aspects --------------------- None as long as all the above constraints are possible (which implies carrying out the main block before mid August, approximately) - no compromise can be done about the sky being dark or science objectives will not be reached. Special Calibration Information ------------------------------- The photometric programme requires several observations of the Landolt field SA110-362. This happens to be a FORS1 standard field. We certainly need Field 1 -------- Lan 110-362 V=15.69 U=20.95 Lan 110-L1 V=16.25 U=20.96 Lan 110-360 V=14.62 U=16.35 Four other standard stars in field are very bright and therefore not too relevant. As this is a FORS1 standard field and there is already a template for it (Photom-std-SA110-high), I am not including OBs for this field. It could be used by the SA on site as the standard calibration target, but I am assuming that the observations will be taken out of our allocated time (in case the SA wants to use some other standard field). Note that we only need observations in VRI filters. We will need observations of this field at three different airmasses: 1) z<1.3 2) 1.41.9 I am assuming 12-min will be needed for each of these exposure, as for the other field. The other calibration field we want is SA110-315 Field 2 -------- Lan 110-311 V=15.51 U=18.48 Lan 110-312 V=16.09 U=16.62 Lan 110-316 V=14.82 U=20.91 Again there are two bright standards in the field, which will probably saturate. Spectral types for Landolt standards are not provided and I don't see how they could help the observations ToO Information --------------- Pre-Imaging Requirements ------------------------ OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 5 Total Number of Submitted Finding Charts: 1 I have created 4 OBs for the target cluster. For V there is one deep observation, divided into 4 1120-s dithered exposures. As this exceeds the total OB size of 1 hour, I have divided it into two OBs. The first one (wd1-V) contains three of the dithers, while the second one (wd1-V-2) contains the fourth For R, there is one single observation divided into 3 250-s dithered exposures (Wd1-R) For I, there is one single observation divided into 3 40-s dithered exposures (Wd1-I) This field should be identified with finding chart wd1_finder.ps Please note that the cluster will not be evident at all in the V frame, but, from experience, it is clearly visible on a TV monitor. I have created no OBs for the main calibration field as this is a FORS1 standard field. I have created 1 OB for standard field 2. It is called L315_VRI. It contains the following exposures: V band 1x1s R band 1x1s I band 3x0.3s dithered exposures List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA]y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA]y Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA]y [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA]y [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA]na [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA]na [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA]na [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]na [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA]na [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y/N/NA]na If you answered "NO" to any of these questions, please revise your OBs *before* submission.