README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID: 71.D-0141(A) Principal Investigator Name: Dietrich Baade Principal Investigator E-mail Address: dbaade@eso.org Principal Investigator Telephone Number: +49-89-3200-6388 Principal Investigator Postal Address: ESO Karl-Schwarzschild-Str. 2 85748 Garching b. Muenchen Instrument: FORS1 OPC Priority Class: A OPC Approved Total Execution Time: 29 hrs Estimated Total Execution Time (including overheads): ToO README File Submission Date: March 05, 2003 Programme Description ===================== General Overview ---------------- We aim for spectroplarimetry of SNe with a precision of 0.1%. These SNe are yet to be discovered. Therefore, this is a ToO project. If sufficiently bright SNe are discovered during P71, we will request observations to be repeated at intervals ranging from a couple of days to a month. Because the magnitudes and their evolution with time are not known in advance, exposure times can only be specified at the time of activation. For the same reason, the identity of the flux standards needs to be left open for the time being. We only submit one generic OB each for (1) an SN science exposure, (2) a science exposure of a spectroscopic flux standard, and (3) daytime calibrations. For each execution of an OB of type (1), we will request one execution of both (2) and (3) within two or three days. If two or more SNe can be observed within such an interval, only one standard star exposure (2) and one set of lamp calibrations (3) will be required. Often SNe are not too blue so that an order-sorting filter can be omitted in favour of an an extension of the wavelength coverage to the blue. To this end, a second OB without order-sorting filter is prepared but otherwise identical to (1), (2) and (3), respectively. Since we will select relatively bright and reasonably well isolated SNe, the OBs will be finalized without FIMS, i.e. using the "fast" template flavour. Approved Waiver Request Summary ------------------------------- A waiver of the 1-hr limit on the execution time of single OBs was granted on March 05 (for technical reasons, the formal approval by Paranal was at the time of submission still pending). Critical Observing Condition Constraints ---------------------------------------- None really. Time Critical Aspects --------------------- The first observation of each SN should be done as early as reasonably possible. The later observations can be made with an increasing level of flexibility ranging from +-1-2 to +-2-3 days. The polarization of SNe of Type Ia declines rapidly after optical maximum while the one of core-collapse SNe continues to grow until well after maximum. Accordingly, the corresponding series of observations (about 3-6 per SN) will cover different periods of time. There are no reasl-time requirements. Special Calibration Information ------------------------------- None. ToO Information --------------- This is a ToO programme. Pre-Imaging Requirements ------------------------ Not required. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- #135268 SN with order-sorting filter #135251 SN WITHOUT order-sorting filter #136084 spectrophotometric standard star with order-sorting filter #136085 spectrophotometric standard star WITHOUT order-sorting filter Total Number of Submitted Science OBs: 4 Total Number of Submitted Finding Charts: 0 (ToO) List of Calibration OBs with Associated Science OBs -------------- #136082 FF + arc lamps WITHOUT order-sorting filter #136083 FF + arc lamps with order-sorting filter ------------------------------------- Total Number of Submitted Calibration OBs: 2 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] Y [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] Y [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] Y [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y/N/NA] If you answered "NO" to any of these questions, please revise your OBs *before* submission.