README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID: 71.D-0014(A) Principal Investigator Name: Alexander Scholz Principal Investigator E-mail Address: scholz@tls-tautenburg.de Principal Investigator Telephone Number: 0049-36427-863-67 Principal Investigator Postal Address: Thüringer Landessternwarte Tautenburg, Sternwarte 5, 07778 Tautenburg, Germany Instrument: WFI OPC Priority Class: B OPC Approved Total Execution Time: 15 hours Estimated Total Execution Time (including overheads): 14:59:45.000 README File Submission Date: Tuesday, 4th March, 2003 Programme Description ===================== General Overview ---------------- This program monitors a field in the open cluster NGC6475. Each OB (see the one exception below) takes five I-band exposures of the field at the same position, without any dithering. The scientific objective of the project is the determination of photometric rotation periods of low-mass cluster members. The herewith defined observations supplement a larger program that will be executed in Max Planck time, which starts at the 5th of August. They will extend the time baseline to register slow rotators. Therefore, it is indispensable that the OBs for this program will be executed either in the 7 nights before the Max Planck time (OBs NGC6475_1 to _7, ZERO_NGC6475) or in the 10 service nights (8th Sep - 17th Sep) after the Max Planck time (NGC6475_8 to _14), as indicated in the 'Time Interval' of the OBs. The observations should be distributed uniformly over these time windows, to ensure uniform sampling. As a rule of thumb, you should execute not more than two OBs in one night. One OB (ZERO_NGC6475) is used to calibrate the field photometrically. It takes three deep exposures in I, R and V. These images will also contribute to the time series, therefore the time interval constraints also apply for this OB. To guarantee exact field centering, we deliver two finding charts. The file 71.D-0014A.001.ps is a 34' x 34' DSS image showing the whole field of view. The file 71.D-0014A.002.ps is a close-up from a former WFI image, showing the central part of the field. The marked star should be centered on pixel (3536,3226) in the WFI mosaic. Approved Waiver Request Summary ------------------------------- We needed NO waiver request. Critical Observing Condition Constraints ---------------------------------------- The 14 time series OBs (NGC6475-1 ... 14) need no photometric conditions, since we are only interested in relative photometry. The calibration OB (ZERO_NGC6475) must be executed under photometric conditions. Time Critical Aspects --------------------- As indicated above, the execution of this program is time critical, since it complements observations in Max Planck time. The OBs NGC6475_1 to _7 and ZERO_NGC6475 must be executed in the service nights 29th July to 4th August. The remaining OBs (NGC6475_8 to _14) must be executed in the service nights after the Max Planck time, between 8th and 17th September. The OBs should be distributed uniformly in these time windows. As a rule of thumb, EXECUTE NOT MORE THAN TWO OBs IN ONE NIGHT. Special Calibration Information ------------------------------- No special calibration images are needed. For every observing night, we need bias and twilight flats from the WFI calibration plan. We deliver one calibration OB (ZERO_NGC6475), which must be executed under photometric conditions. For this OB, we require the observation of Landolt fields in the standard filters I/203, Rc/162, V/89 in the same night, preferably with small time-lag to the NGC6475 field. Therefore, we need photometric calibration from the WFI calibration plan, i.e. we request PCa. ToO Information --------------- This is no ToO program. Pre-Imaging Requirements ------------------------ We need no Pre-Imaging. OB Information ============== List of Science OBs with Associated Finding Charts -------------------------------------------------- ZERO_NGC6475 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-14 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-13 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-12 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-11 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-10 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-9 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-8 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-7 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-6 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-5 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-4 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-3 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-2 71.D-0014A.001.ps and 71.D-0014A.002.ps NGC6475-1 71.D-0014A.001.ps and 71.D-0014A.002.ps Total Number of Submitted Science OBs: 15 Total Number of Submitted Finding Charts: 2 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Total Number of Submitted Calibration OBs: 0 OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y] If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [NA] Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y] [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA] [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [NA] [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [NA] [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [NA] [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [NA] [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y] If you answered "NO" to any of these questions, please revise your OBs *before* submission.