README Template 71.1 (please do not delete the README Template Version line!) ESO Programme ID:71.B-0525(A ) Principal Investigator Name:L. Pentericci Principal Investigator E-mail Address: laura@mpia.de Principal Investigator Telephone Number:49-6221-528383 Principal Investigator Postal Address: MPIA, Konigstuhl 17 Heidelberg Germany Instrument: ISAAC OPC Priority Class: A OPC Approved Total Execution Time: 16hours Estimated Total Execution Time (including overheads): README File Submission Date: Programme Description ===================== General Overview ---------------- The program consists of K-band spctroscopic observations of the second most distant QSOs to detect the FeII and MgII emission line We will observe the object in short wavelength low resolution mode in K band (2.2 micron central wav) ACQUISITION STRATEGY The main problem is the aquisition since the target is very faint and has a very bright star nearby. -The K band of the QSO is unknown but from the J-band (18.9) we can estimate a K band magnitude of 17.5 or fainter. The magnitude of the very bright star is about 12 magnitude in R band (the exact K band magnitude is not known but could be brightern than 11 magnitudes ) and will surely enter the field during acquisition. So we prefer to do the acquisition of the slit on a nearby star (which is ccalle REFSTAR1030, magnitude z=18, K band mag. unknown but possibly around 15-16). also becasue the integration time in the acquisition must be kept short For acquisition template we introduce a narrow band filter and keep the DIT time quite short (5seconds) to avoid saturation but the NDIT is 20 in order to still have about 100 sec imaging for the acquisition (otherwise the reference star will not be visible) Approved Waiver Request Summary ------------------------------- Critical Observing Condition Constraints ---------------------------------------- Observations should be performed at airmass below 1.5 Time Critical Aspects --------------------- Special Calibration Information ------------------------------- No special calibration is required: a standard telluric star should be observed at a similar airmass within the standard calibration. PLEASE do observe it with the same setup!! (i had the observations done with a different set up in more than one occasion during the past runs) ToO Information --------------- Pre-Imaging Requirements ------------------------ OB Information ============== QSO1030_1 finding chart 71.B-0525A.001.ps QSO1030_2 finding chart 71.B-0525A.001.ps QSO1030_3 finding chart 71.B-0525A.001.ps QSO1030_4 finding chart 71.B-0525A.001.ps QSO1030_5 finding chart 71.B-0525A.001.ps QSO1030_6 finding chart 71.B-0525A.001.ps QSO1030_7 finding chart 71.B-0525A.001.ps QSO1030_8 finding chart 71.B-0525A.001.ps QSO1030_9 finding chart 71.B-0525A.001.ps QSO1030_10 finding chart 71.B-0525A.001.ps QSO1030_11 finding chart 71.B-0525A.001.ps QSO1030_12 finding chart 71.B-0525A.001.ps QSO1030_13 finding chart 71.B-0525A.001.ps QSO1030_14 finding chart 71.B-0525A.001.ps QSO1030_15 finding chart 71.B-0525A.001.ps QSO1030_16 finding chart 71.B-0525A.001.ps The finding chart represents the z band emission therefore it could be sliglty different inthe observation band (K band) NB all OBs are the same apart that the last 2 have slightly lower integration time to keep the overall int time to 16 hours! List of Science OBs with Associated Finding Charts -------------------------------------------------- Total Number of Submitted Science OBs: 16 Total Number of Submitted Finding Charts: 1 List of Calibration OBs with Associated Science OBs --------------------------------------------------- Please try to observe the telluric star at the a similar airmass as the science observations. Total Number of Submitted Calibration OBs: none OB Compliance Checks ==================== (Y = Yes, N = No, NA = Not Applicable) Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages ? [Y/N/NA] Y If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars ? [Y/N/NA] NA Have you included OBs for any calibrations that you need but which are not a part of the Calibration Plan? [Y/N/NA] NA [FORS only] Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [Y/N/NA] NA [FORS only] Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [Y/N/NA] NA [UVES only] Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages ? [Y/N/NA] NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page ? [Y/N/NA] Y [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA] NA [FLAMES only] Did you specify the hour angle range for which your Target Setup files are valid ? [Y/N/NA] NA [WFI only]Are your finding charts 34 arcmin x 34 arcmin? [Y/N/NA] NA If you answered "NO" to any of these questions, please revise your OBs *before* submission. Y = Yes, N = No, NA = Not Applicable Do all your OBs comply with the instrument specific requirements listed on the instrument specific Phase 2 Web pages [Y/N/NA]? Y Do all your FORS OBs use only the allowed detector read-out modes listed on the FORS1/FORS2 Phase 2 Web pages? [NA] NA Do all your FORS MOS/LSS OBs contain the mandatory "through-slit image" template? [NA]? NA Did you submit the mandatory calibration OBs for each FORS MOS mask setup [NA]? NA Do all your UVES OBs use only the allowed templates listed on the UVES Phase 2 Web pages [NA]? NA If you submitted OBs for standard stars, did you specify the magnitude and spectral type of all standard stars [Y/N/NA]? NA [ISAAC only] Are ALL the objects in your field-of-view fainter than the magnitude limits specified on the ISAAC Phase 2 Web page [Y/N/NA]? YES BUT READ CAREFULLY ABOVE! [ISAAC only] If you submitted OBs for standard stars, did you use the provided StandardStar templates? [Y/N/NA]? If you answered "NO" to any of these questions, please revise your OBs *before* submission. Destination Address for Data Products ===================================== Laura Pentericci MPIA Konigstuhl 17 69117 Heidelberg Germany *************************************** DO NOT WRITE BELOW THESE LINES!!!!!!!!! ***************************************